The best thing about my water cooling and floor heating is that my wife keeps nagging me to buy a second 5970 to make the floor warmer. Beat this with a air cooled system. :-)
You are the friggen man... that is like the best idea i've seen lately. whats the watter temps upon entering the floor?
Thanks for the compliments, folks! Water temperature is currently ~31°C when entering and 26°C when leaving the floor. This morning the floor held ~23°C. Outside temp is 0°C and the hall outside the door was ~15°C after a cold and snowy night.
WOW indeed. I though I was crazy enough... so I am guessing in Norway houses are heated year-around, correct? otherwise it would cost you a lot more if you have to use AC pumping those heat out.
We don't have AC. The sun heats the house in summer, and we open a window or door if it gets too warm inside. The bathroom floor will be heated all year, but we don't need as much heat in the summer. I live on the western edge of the country, where we have mild winters (lowest I have measured is -10°C) and cold summers (seldom above 25°C, mostly 10-20°C). Statistics
here. The plan is to measure temperature and humidity with my sensors, and regulate clock speed and fan according to that and weather on the outside. I also have another plan..
Sturle, wow ... I was wondering about feasibility on this ... typical domestic hot water can be in 4-6 kWatt range ... about 7-8 HD 5970 cards ... combined heat and GPU power CHGPU solution (i.e. not CHP). Clever way to turn useless heater element resistor in hot water tank into GPU transistor and get computational power (bitcoins) as a bonus.
Step two in my plan is to let the water in the computer circulate through a heat exchanger which pre-heats water before entering our hot water tank. In the loop I will also have a small used hot water tank, perhaps around 50l, to buffer the heat between showers and baths where a lot of hot water is used at once. Is this drawing understandable?
____________ ____ pre-heated water to tank
/ _|_ buffer ><
Computer / | | tank <> -heat exchanger
\ |_ _| ><
\__|__________<>_____ cold water in
This will not heat water all they way to hot tap water temperature, but it will do much of the work.
I will not have tap water circulating through my computer because of pressure conditions and the devastating results in case of a leak. Total amount of water in my system is about 3l, and a leak will not do much damage. Tap water in unlimited supply will. I will have a plumber install the heat exchanger connected to my hot water tank.