Author

Topic: S9j 0 hashing (Read 78 times)

newbie
Activity: 11
Merit: 4
May 27, 2022, 02:24:08 AM
#4
I think the control board is broken.
newbie
Activity: 28
Merit: 4
May 26, 2022, 06:09:33 PM
#3
Thank you for your help
legendary
Activity: 3206
Merit: 2904
Block halving is coming.
May 26, 2022, 01:13:24 PM
#2
Based on the logs below read temp error it means that your control board can't detect any temp signal from your hashboard.

Code:
Max pcb temp : 0
Read temp failed, set fixed full fan speed
FAN PWM: 100
read_temp_func Done!
CRC error counter=268

One of your hash boards might have a broken temp sensor or ribbon wires that are not plugged properly.

Try to re-plug all of your ribbon wires then check it again through logs or if it's hashing.

If still do not work then you can bypass this issue by flashing your unit with modded firmware like asic.to firmware or Braiins OS.
newbie
Activity: 28
Merit: 4
May 26, 2022, 09:11:57 AM
#1
Hello everyone, i am facing a problem to one of my S9J's that not hashing. PSU Working fine

here is kernel log:

https://pastebin.com/fMWvqc8r

Thanks in advance
Jump to: