Hi,
My M20s was working fine up until recently when there was a move to a new router.
I moved it back to the old router and did a factory reset (it wasn't appearing in IP scanner at all), then flashed from an SD card and updated to the latest firmware.
That made it contactable. I put back in the pool settings, making sure they're straight copy-pastes from the other miners that are working on the same router other than worker ID, but this issue appears where it gets stuck restarting cgminer repeatedly:
-19 20:35:48 02-19 20:35:48 Restart cgminer as as No cgminer
02-19 20:35:51 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|0,0
02-19 20:36:22 0,0,0|0,0,0|0,0,0|0,0|0,2%,215|0,0
02-19 20:36:27 02-19 20:36:27 Restart cgminer as as No cgminer
02-19 20:36:52 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|0,0
02-19 20:37:06 02-19 20:37:06 Restart cgminer as as No cgminer
02-19 20:37:22 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|0,0
02-19 20:37:46 02-19 20:37:46 Restart cgminer as as No cgminer
02-19 20:37:52 0,0,0|0,0,0|0,0,0|0,0|0,0%,214|0,0
02-19 20:38:23 0,0,0|0,0,0|0,0,0|0,0|0,0%,214|0,0
02-19 20:38:25 02-19 20:38:25 Restart cgminer as as No cgminer
02-19 20:38:53 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|0,0
02-19 20:39:04 02-19 20:39:04 Restart cgminer as as No cgminer
02-19 20:39:23 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:39:44 02-19 20:39:44 Restart cgminer as as No cgminer
02-19 20:39:53 0,0,0|0,0,0|0,0,0|0,0|0,2%,214|0,0
02-19 20:40:23 02-19 20:40:23 Restart cgminer as as No cgminer
02-19 20:40:23 0,0,0|0,0,0|0,0,0|0,0|0,2%,214|0,0
02-19 20:40:54 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:41:02 02-19 20:41:02 Restart cgminer as as No cgminer
02-19 20:41:24 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:41:42 02-19 20:41:42 Restart cgminer as as No cgminer
02-19 20:41:54 0,0,0|0,0,0|0,0,0|0,0|0,19%,212|0,0
02-19 20:42:21 02-19 20:42:21 Restart cgminer as as No cgminer
02-19 20:42:24 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:42:56 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:43:00 02-19 20:43:00 Restart cgminer as as No cgminer
02-19 20:43:13 Error code: 210, reason: Power error status:
0x0000->0x0001
power name:P21 vender:1 hw: sw:102218.009 sn:62Ca193502417
02-19 20:43:03 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:113 temp1:140 temp2:121
status:0
02-19 20:43:04 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3780 temp0:123 temp1:142 temp2:126
status:0
02-19 20:43:05 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:118 temp1:139 temp2:122
status:0
02-19 20:43:06 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3840 temp0:122 temp1:136 temp2:127
status:0
02-19 20:43:07 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3840 temp0:113 temp1:139 temp2:121
status:0
02-19 20:43:08 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:121 temp1:138 temp2:124
status:0
02-19 20:43:09 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:119 temp1:142 temp2:128
status:0
02-19 20:43:10 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3780 temp0:117 temp1:134 temp2:130
status:0
02-19 20:43:11 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:115 temp1:142 temp2:118
status:0
02-19 20:43:12 power enable:0 errors:1 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3900 temp0:112 temp1:142 temp2:119
status:0
02-19 20:43:13 power enable:0 errors:1 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:4170 temp0:122 temp1:141 temp2:130
status:20000
02-19 20:43:13 power enable:0 errors:1 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:4170 temp0:122 temp1:141 temp2:130
status:20000
02-19 20:43:14 power enable:0 errors:1 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:4440 temp0:123 temp1:142 temp2:130
status:20000
01-02 08:00:04 Miner M20SV10 start, MAC: C4:07:11:00:8D:4D, version:
'20220128.19.REL' PCB0:H8M14S69129910B50193 PCB1:H8M14S69129910B50227
PCB2:H8M14S69129910B50190
01-02 08:00:06 Error code: 2010, reason: All pools disabled for 2s,
please check the network or pools configure.
02-19 21:54:28 0,0,0|0,0,0|0,0,0|0,0|0,2%,227|0,0
02-19 21:54:31 Error code: 110, reason: Fan in detect speed error
02-19 21:54:31 Error code: 111, reason: Fan out detect speed error
02-19 21:54:39 02-19 21:54:39 Restart cgminer as as No cgminer
02-19 21:54:58 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|1,0
02-19 21:55:19 02-19 21:55:19 Restart cgminer as as No cgminer
02-19 21:55:28 0,0,0|0,0,0|0,0,0|0,0|0,0%,216|1,0
02-19 21:55:58 02-19 21:55:58 Restart cgminer as as No cgminer
02-19 21:55:58 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|1,0
02-19 21:56:30 0,0,0|0,0,0|0,0,0|0,0|0,2%,215|1,0
02-19 21:56:37 02-19 21:56:37 Restart cgminer as as No cgminer
02-19 21:56:59 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|1,0
02-19 21:57:17 02-19 21:57:17 Restart cgminer as as No cgminer
02-19 21:57:29 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|1,0
General info on box including API log:
https://imgur.com/a/WHlR4SGI think the pool password error is a false flag, the pool state change logs show it being set back to the correct value.
What I'm not sure about is if this is a network error or hardware one. I think I had the warnings about the fans before, and the miner ignored them and mined anyway. It also seems unlikely that both would fail around the same time.
It's connected to a TPLink modem that has an integrated 4 way switch that has works fine for the other boxes.
Thanks