Author

Topic: Whatsminer M20s: Socket connection refused (Read 58 times)

legendary
Activity: 3234
Merit: 2943
Block halving is coming.
February 20, 2022, 01:53:43 PM
#2
Why not try to replug the fan first? Since API logs pointing the fan issue it might be the reason why its not hashing.

Also try to mine on other pools if you fill there is something  issue on the miner connecting to the pool.You can try viabtc or look here https://miningpoolstats.stream/bitcoin

Take note of extra spaces it won't work properly if there is extra space or just manually type the pool instead of pasting it.
newbie
Activity: 2
Merit: 0
February 20, 2022, 09:46:28 AM
#1
Hi,
My M20s was working fine up until recently when there was a move to a new router.

I moved it back to the old router and did a factory reset (it wasn't appearing in IP scanner at all), then flashed from an SD card and updated to the latest firmware.
That made it contactable. I put back in the pool settings, making sure they're straight copy-pastes from the other miners that are working on the same router other than worker ID, but this issue appears where it gets stuck restarting cgminer repeatedly:

Code:
-19 20:35:48 02-19 20:35:48 Restart cgminer as as No cgminer
02-19 20:35:51 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|0,0
02-19 20:36:22 0,0,0|0,0,0|0,0,0|0,0|0,2%,215|0,0
02-19 20:36:27 02-19 20:36:27 Restart cgminer as as No cgminer
02-19 20:36:52 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|0,0
02-19 20:37:06 02-19 20:37:06 Restart cgminer as as No cgminer
02-19 20:37:22 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|0,0
02-19 20:37:46 02-19 20:37:46 Restart cgminer as as No cgminer
02-19 20:37:52 0,0,0|0,0,0|0,0,0|0,0|0,0%,214|0,0
02-19 20:38:23 0,0,0|0,0,0|0,0,0|0,0|0,0%,214|0,0
02-19 20:38:25 02-19 20:38:25 Restart cgminer as as No cgminer
02-19 20:38:53 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|0,0
02-19 20:39:04 02-19 20:39:04 Restart cgminer as as No cgminer
02-19 20:39:23 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:39:44 02-19 20:39:44 Restart cgminer as as No cgminer
02-19 20:39:53 0,0,0|0,0,0|0,0,0|0,0|0,2%,214|0,0
02-19 20:40:23 02-19 20:40:23 Restart cgminer as as No cgminer
02-19 20:40:23 0,0,0|0,0,0|0,0,0|0,0|0,2%,214|0,0
02-19 20:40:54 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:41:02 02-19 20:41:02 Restart cgminer as as No cgminer
02-19 20:41:24 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:41:42 02-19 20:41:42 Restart cgminer as as No cgminer
02-19 20:41:54 0,0,0|0,0,0|0,0,0|0,0|0,19%,212|0,0
02-19 20:42:21 02-19 20:42:21 Restart cgminer as as No cgminer
02-19 20:42:24 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:42:56 0,0,0|0,0,0|0,0,0|0,0|0,0%,213|0,0
02-19 20:43:00 02-19 20:43:00 Restart cgminer as as No cgminer
02-19 20:43:13 Error code: 210, reason: Power error status:
0x0000->0x0001
power name:P21 vender:1 hw: sw:102218.009 sn:62Ca193502417
02-19 20:43:03 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:113 temp1:140 temp2:121
status:0
02-19 20:43:04 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3780 temp0:123 temp1:142 temp2:126
status:0
02-19 20:43:05 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:118 temp1:139 temp2:122
status:0
02-19 20:43:06 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3840 temp0:122 temp1:136 temp2:127
status:0
02-19 20:43:07 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3840 temp0:113 temp1:139 temp2:121
status:0
02-19 20:43:08 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:121 temp1:138 temp2:124
status:0
02-19 20:43:09 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:119 temp1:142 temp2:128
status:0
02-19 20:43:10 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3780 temp0:117 temp1:134 temp2:130
status:0
02-19 20:43:11 power enable:0 errors:0 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3810 temp0:115 temp1:142 temp2:118
status:0
02-19 20:43:12 power enable:0 errors:1 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:3900 temp0:112 temp1:142 temp2:119
status:0
02-19 20:43:13 power enable:0 errors:1 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:4170 temp0:122 temp1:141 temp2:130
status:20000
02-19 20:43:13 power enable:0 errors:1 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:4170 temp0:122 temp1:141 temp2:130
status:20000
02-19 20:43:14 power enable:0 errors:1 iout:0 vout:0 vout_set:0 iin:-1
vin:-1 input_power:0 fan_speed:4440 temp0:123 temp1:142 temp2:130
status:20000
01-02 08:00:04 Miner M20SV10 start, MAC: C4:07:11:00:8D:4D, version:
'20220128.19.REL' PCB0:H8M14S69129910B50193 PCB1:H8M14S69129910B50227
PCB2:H8M14S69129910B50190
01-02 08:00:06 Error code: 2010, reason: All pools disabled for 2s,
please check the network or pools configure.
02-19 21:54:28 0,0,0|0,0,0|0,0,0|0,0|0,2%,227|0,0
02-19 21:54:31 Error code: 110, reason: Fan in detect speed error
02-19 21:54:31 Error code: 111, reason: Fan out detect speed error
02-19 21:54:39 02-19 21:54:39 Restart cgminer as as No cgminer
02-19 21:54:58 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|1,0
02-19 21:55:19 02-19 21:55:19 Restart cgminer as as No cgminer
02-19 21:55:28 0,0,0|0,0,0|0,0,0|0,0|0,0%,216|1,0
02-19 21:55:58 02-19 21:55:58 Restart cgminer as as No cgminer
02-19 21:55:58 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|1,0
02-19 21:56:30 0,0,0|0,0,0|0,0,0|0,0|0,2%,215|1,0
02-19 21:56:37 02-19 21:56:37 Restart cgminer as as No cgminer
02-19 21:56:59 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|1,0
02-19 21:57:17 02-19 21:57:17 Restart cgminer as as No cgminer
02-19 21:57:29 0,0,0|0,0,0|0,0,0|0,0|0,0%,215|1,0

General info on box including API log:

https://imgur.com/a/WHlR4SG

I think the pool password error is a false flag, the pool state change logs show it being set back to the correct value.

What I'm not sure about is if this is a network error or hardware one. I think I had the warnings about the fans before, and the miner ignored them and mined anyway. It also seems unlikely that both would fail around the same time.

It's connected to a TPLink modem that has an integrated 4 way switch that has works fine for the other boxes.

Thanks
Jump to: