Pages:
Author

Topic: [Setup & Troubleshoot] Bitmain AntMiner S1 180GH/S miner - page 32. (Read 452359 times)

legendary
Activity: 1876
Merit: 1000

has anyone used public/private keys to access the ants ?  

I am always prompted for the password after setting up keys.

bump... anyone using ssh and pub/priv keys?
newbie
Activity: 19
Merit: 0
It's getting warm out here (almost 80 degree F) so I don't think just the open window is going to work to keep these things cool.  I have 8 in a row and the warmest has hit 62 degrees.  I read that you should keep them below 60 and definitely below 70.  Are these numbers accurate or should I add some a/c asap?
legendary
Activity: 1722
Merit: 1005
The system/software field will never update.  I asked this question a few pages back.  You can verify the version by typing a command in the SSH shell.  cgminer -V, I think.

PERFECT!!! , This was my error. I can see the it.

cgminer 4.2.2a

Thank you very much.
Regards.
Antuam
full member
Activity: 210
Merit: 100
Tip:

If you haven't upgraded your CG miner to 4.2.2a I HIGHLY suggest you do.  I did 24 hours ago, and my HW error rate is 60% lower, and temps 2 deg C lower as well.

Don't know what changed, but I like it!

I followed the directions below TO THE LETTER and it worked like a charm!

https://github.com/kanoi/cgminer-binaries/tree/master/AntS1

Hello.
I would like update the CGMINER.  I do all in the post but If I go to SYSTEM / SOFTWARE, I see CGMINER Versión 3.12.0-1.

Could you help me ,please?.

Thank you in advanced.
Antuam

The system/software field will never update.  I asked this question a few pages back.  You can verify the version by typing a command in the SSH shell.  cgminer -V, I think.
legendary
Activity: 1722
Merit: 1005
Tip:

If you haven't upgraded your CG miner to 4.2.2a I HIGHLY suggest you do.  I did 24 hours ago, and my HW error rate is 60% lower, and temps 2 deg C lower as well.

Don't know what changed, but I like it!

I followed the directions below TO THE LETTER and it worked like a charm!

https://github.com/kanoi/cgminer-binaries/tree/master/AntS1

Hello.
I would like update the CGMINER.  I do all in the post but If I go to SYSTEM / SOFTWARE, I see CGMINER Versión 3.12.0-1.

Could you help me ,please?.

Thank you in advanced.
Antuam

hero member
Activity: 882
Merit: 501
Ching-Chang;Ding-Dong
ship the broken device to bitmain back if you within 90 days of waranty!

i had a problem with the lan adapter on my device and this was a communication with bitmain support!

Hi Dimitri,

please just ship back the bad parts to bellow address, and mark your name and order ID in the package.Â
----------------------------------------------------------------------
Building No.13-16, Jiu Wei New Village, Xixiang Street, BaoAn District, Shenzhen, 518126, China

Contact: Gao JianPing

----------------------------------------------------------------------

please share us your tracking number after you ship out, when we receive it, we will re-ship good replacement to you.


Best Regards

 

BITMAIN


Good to new, a couple of mine units also have bad ethernet ports Sad
newbie
Activity: 42
Merit: 0
Tip:

If you haven't upgraded your CG miner to 4.2.2a I HIGHLY suggest you do.  I did 24 hours ago, and my HW error rate is 60% lower, and temps 2 deg C lower as well.

Don't know what changed, but I like it!

I followed the directions below TO THE LETTER and it worked like a charm!

https://github.com/kanoi/cgminer-binaries/tree/master/AntS1
sr. member
Activity: 350
Merit: 250
Co-Owner Of DCMCo-Op Mining Farm at 3.5 th/s
that is a common thing with ssh connections
that key is so that the ssh server knows that you are who you claim to be besides just having the password
legendary
Activity: 1876
Merit: 1000

has anyone used public/private keys to access the ants ?  

I am always prompted for the password after setting up keys.
legendary
Activity: 1386
Merit: 1004
I have one unit that is not mining.  It sees no mining chains.  I get none of those lines of oooooooooooooooooooo on the status page.  What could cause that?
hero member
Activity: 546
Merit: 500
mine is running steady at 200ghs.
Added an extra fan, cut 2 cables per fan, the control cables so they run at 100%
Added plexi, turned it upside down. somehow this took away 3°C
Running smooth @ 39&40°C

Does putting the case around the S1 help in any way. I seem to notice it colder on the top of the heatsync and hot air blowing out the proper sides.

I still have default fans and would like to get the air to where it's needed to try and  keep the fans from cranking up. It's still on my wishlist to quell the ant miners screams.
legendary
Activity: 1018
Merit: 1001

The S1 uses non-standard connectors.  Clip one side of the plastic guard with wire-cutters and plug it in anyways.

Thanks Raptor2213
full member
Activity: 210
Merit: 100
Hi, I bought a PWM fan Coolink SWIF2 120P to be added to the S1, but the connector on the balde is different, and not fit. Which fan should I buy compatible with the S1 PWM connector.

Thanks in advance W_M

The S1 uses non-standard connectors.  Clip one side of the plastic guard with wire-cutters and plug it in anyways.
legendary
Activity: 1018
Merit: 1001
Hi, I bought a PWM fan Coolink SWIF2 120P to be added to the S1, but the connector on the balde is different, and not fit. Which fan should I buy compatible with the S1 PWM connector.

Thanks in advance W_M

sr. member
Activity: 322
Merit: 250
Just found an awesome deal on Newegg... 120mm Bgears case fan, they have 103 CFM rating, might be loud (35dba) but I don't care about noise at these prices. Promo code pricing and a sale, I got 5 of them for $26.95!! What I will probably do is swap these onto my blades to replace most of the array of Coolermaster ~70CFM SickleFlow fans I have running, and then I'll put those old CoolerMaster fans on my Antminers pulling side. My rack of blades seems to be suffering with the weather getting warm, or maybe just length of time/use, but I'd like to push more air across them for low dollars before I start messing around with thermal compound, and this will free up a few of my other fans to throw on the Antminers, at least temporarily worth a shot.
sr. member
Activity: 322
Merit: 250
Is this fan good for the front of these? (Ie, to pull air from opposite side of OEM fan)

http://www.newegg.com/Product/Product.aspx?Item=N82E16835705040

From what I've seen this looks like good bang for the buck, right?
Not bad. I usually buy fans between 110-130 cfm though. Gives more pulling power.

Is there a particular brand you recommend?
newbie
Activity: 15
Merit: 0
Is this fan good for the front of these? (Ie, to pull air from opposite side of OEM fan)

http://www.newegg.com/Product/Product.aspx?Item=N82E16835705040

From what I've seen this looks like good bang for the buck, right?
Not bad. I usually buy fans between 110-130 cfm though. Gives more pulling power.

I cant get it to work. cgminer doesnt start after that update
btw: is there no command for shutdown the ants??
legendary
Activity: 1593
Merit: 1004
Is this fan good for the front of these? (Ie, to pull air from opposite side of OEM fan)

http://www.newegg.com/Product/Product.aspx?Item=N82E16835705040

From what I've seen this looks like good bang for the buck, right?
Not bad. I usually buy fans between 110-130 cfm though. Gives more pulling power.
sr. member
Activity: 434
Merit: 250
hi all,

how can i configure the S1 to shutdown if a critical temperature reaches ...
i dont trust the units and i cant watch them 24/7 .

there is a command --bitmain-temp  but how can i use it?
I cant find anything at the webinterface.


thx
Wurzelsepp

I don't have an answer but what is considered "critical temperature"? Weather is getting warm here and mine are running at 47c... I might add a fan pulling from the front, but the most recommended brand seems discontinued.

if you have only 1 pool configured add it to the line of the password like Password: x --bitmain-temp 65

It won't work unless you use the custom cgminer build that I showed you.

(if anyone else is interested: https://github.com/kanoi/cgminer-binaries/tree/master/AntS1)
sr. member
Activity: 350
Merit: 250
Co-Owner Of DCMCo-Op Mining Farm at 3.5 th/s
hi all,

how can i configure the S1 to shutdown if a critical temperature reaches ...
i dont trust the units and i cant watch them 24/7 .

there is a command --bitmain-temp  but how can i use it?
I cant find anything at the webinterface.


thx
Wurzelsepp

I don't have an answer but what is considered "critical temperature"? Weather is getting warm here and mine are running at 47c... I might add a fan pulling from the front, but the most recommended brand seems discontinued.

if you have only 1 pool configured add it to the line of the password like Password: x --bitmain-temp 65