What can I do about following problem:
I have two blades running on high clock with enough(!) air cooling which menas 2x 120mm fans on the sinks and 1x 120mm fan on the back to get air circulation on the back. And this fans does cool each of the blades.

Now I´m running a stratum proxy on a RSPi which also runns fine. But from time to time the blades seem to restart and at the time of my notice they have run for about 4-10 hours on low clock speed.

What can be the problem here? What about some ideas to prevent this?

The blade restarts when it is not getting any work. One problem would be pool servers. I have faced this problem when using a less stable pool.
Also friedcat confirmed that when a blade restarts, it picks low or high clock based on the voltage that it has at its disposal or something on those lines.
newbie
Activity: 32
Merit: 0
What can I do about following problem:
I have two blades running on high clock with enough(!) air cooling which menas 2x 120mm fans on the sinks and 1x 120mm fan on the back to get air circulation on the back. And this fans does cool each of the blades.

Now I´m running a stratum proxy on a RSPi which also runns fine. But from time to time the blades seem to restart and at the time of my notice they have run for about 4-10 hours on low clock speed.

What can be the problem here? What about some ideas to prevent this?
hero member
Activity: 518
Merit: 500
BTC < > INR & USD
Latest layout:

Wind tunnel design helps a LOT, conveys all the heat up and away. Everything much cooler and with lower fan speeds.


Couldn't agree more.! That wind tunnel really helps.
My mounting case is also designed keeping that in mind.!

Side view : Here you can see blades and 2 fans at the bottom. The fans on the heat sinks are fixed to the frame using the corner brackets and the blade is fixed to the fan using the cable ties. It is pretty rock solid and firm. No vibration or noise of any kind.



Close up of Side View



View of the complete setup. Apart from the 6 X 120 mm fans, i have a Honeywell HT-900 table fan blowing from the side to keep the entire system cool.



legendary
Activity: 1666
Merit: 1185
dogiecoin.com
Latest layout:

Wind tunnel design helps a LOT, conveys all the heat up and away. Everything much cooler and with lower fan speeds.
hero member
Activity: 1316
Merit: 503
Someone is sitting in the shade today...
thank you Smiley  i will leave it as it is
sr. member
Activity: 335
Merit: 250

3) Is the stratum server suppose to spam so much?  i am getting a nonstop stream of spam with below text, is there anything wrong with it? i am using all default settings. 

That's not spam, that's logging. If you aren't interested in the mechanics you can run it with the -q flag to drop it down to just submissions.
sr. member
Activity: 333
Merit: 250
Commander of the Hodl Legions
Hi guys, i just got my asic blade setup and have a few questions.

1) is there anyway to monitor the temperature? i dont see any temperature readings in the setting screen and the heatsink is very hot to the touch so i am a little worried

2) Is there anyway to access the setup screen while outside of the network? for example if i am at work is there a way to see or config the setup screen remotely? 

3) Is the stratum server suppose to spam so much?  i am getting a nonstop stream of spam with below text, is there anything wrong with it? i am using all default settings. 

Thanks!

1) There are fan controllers with sensors. Also, you can use arduino sensors if you have an arduino.
2) VPN (secure & recommended) or "opening the 8000 WAN port on your router" + no-ip (not so secure / much less recommended)
3) Yup... if you don't like it you can use supervisord and run the proxy script as a "silent" daemon.
hero member
Activity: 1316
Merit: 503
Someone is sitting in the shade today...
Hi guys, i just got my asic blade setup and have a few questions.

1) is there anyway to monitor the temperature? i dont see any temperature readings in the setting screen and the heatsink is very hot to the touch so i am a little worried

2) Is there anyway to access the setup screen while outside of the network? for example if i am at work is there a way to see or config the setup screen remotely? 

3) Is the stratum server suppose to spam so much?  i am getting a nonstop stream of spam with below text, is there anything wrong with it? i am using all default settings.  

Thanks!

Code:
2013-06-03 20:38:53,237 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,318 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,365 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,515 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,524 INFO proxy jobs.submit # Submitting 238b0469
2013-06-03 20:38:53,553 INFO proxy jobs.submit # Submitting 025c9983
2013-06-03 20:38:53,592 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,601 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,616 WARNING proxy getwork_listener._on_submit # [91ms] Share from 'gagaliya.worker1' accepted, diff 1
2013-06-03 20:38:53,645 WARNING proxy getwork_listener._on_submit # [92ms] Share from 'gagaliya.worker1' accepted, diff 1
2013-06-03 20:38:53,697 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,750 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,842 INFO proxy jobs.submit # Submitting 64c43d35
2013-06-03 20:38:53,852 INFO proxy jobs.submit # Submitting 21705f0e
2013-06-03 20:38:53,873 INFO proxy jobs.submit # Submitting fcb480cb
2013-06-03 20:38:53,892 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,932 WARNING proxy getwork_listener._on_submit # [89ms] Share from 'gagaliya.worker1' accepted, diff 1
2013-06-03 20:38:53,944 WARNING proxy getwork_listener._on_submit # [92ms] Share from 'gagaliya.worker1' accepted, diff 1
2013-06-03 20:38:53,948 INFO proxy getwork_listener._on_authorized # Worker 'gagaliya.worker1' asks for new work
2013-06-03 20:38:53,963 WARNING proxy getwork_listener._on_submit # [90ms] Share from 'gagaliya.worker1' accepted, diff 1

full member
Activity: 238
Merit: 100

Hashrate turns to zero and all "x": Either the power module is broken or the whole blade has some problems. If you bought more than one blades. Try using other functional ones' power module to test if it becomes OK. If so please ask us to send you a new power module. If not, please return it back and we will send you a new one (we cover the shipping fee).

Today I received the Blade and I have a problem:
Status chip: xxxxxxxxxxxxxxxxxxxxxxxxx
I have another blade so:
- I checked all the modules and I am sure that the motherboard is damaged. (communication module - ok and power module - ok)
  - Reset to factory settings - nothing has changed.
The device damaged and 50btc frozen,
  any solution? or warranty replacement ?

Send a pm to friedcat.  When I had a potential warranty issue he responded within 24 hours.  Make the subject line visible though with distinctive wording "WARRANTY WORK NEEDED" or something...

Sorry to hear about this.  If it ends up being warranty work, please let us know the turnaround time.
newbie
Activity: 10
Merit: 0

Hashrate turns to zero and all "x": Either the power module is broken or the whole blade has some problems. If you bought more than one blades. Try using other functional ones' power module to test if it becomes OK. If so please ask us to send you a new power module. If not, please return it back and we will send you a new one (we cover the shipping fee).

Today I received the Blade and I have a problem:
Status chip: xxxxxxxxxxxxxxxxxxxxxxxxx
I have another blade so:
- I checked all the modules and I am sure that the motherboard is damaged. (communication module - ok and power module - ok)
  - Reset to factory settings - nothing has changed.
The device damaged and 50btc frozen,
  any solution? or warranty replacement ?
full member
Activity: 238
Merit: 100
my paper clip trick on my powersupply is unstable, I put electrical tape over it (just that part of the connector it covers maybe 5 pins in a row) but it doesn't hold the paper clip down forever, it becomes less effective and the paper clip is able to move just the slightest to turn the power supply off


how do other people deal with this? Its just a minor annoyance because the block erupter blade reboots so quickly and gets back to work
Just make it a bit spring-loaded and plug into two holes next to each other.

Yeah mine requires a decent bit of force to put it in and out. Its also cut to the perfect length so taping is purely to prevent drunk people and cats getting electrocuted.

Drunk cats are out of luck?
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
my paper clip trick on my powersupply is unstable, I put electrical tape over it (just that part of the connector it covers maybe 5 pins in a row) but it doesn't hold the paper clip down forever, it becomes less effective and the paper clip is able to move just the slightest to turn the power supply off


how do other people deal with this? Its just a minor annoyance because the block erupter blade reboots so quickly and gets back to work
Just make it a bit spring-loaded and plug into two holes next to each other.

Yeah mine requires a decent bit of force to put it in and out. Its also cut to the perfect length so taping is purely to prevent drunk people and cats getting electrocuted.
sr. member
Activity: 315
Merit: 250
Official sponsor of Microsoft Corp.
my paper clip trick on my powersupply is unstable, I put electrical tape over it (just that part of the connector it covers maybe 5 pins in a row) but it doesn't hold the paper clip down forever, it becomes less effective and the paper clip is able to move just the slightest to turn the power supply off


how do other people deal with this? Its just a minor annoyance because the block erupter blade reboots so quickly and gets back to work
Just make it a bit spring-loaded and plug into two holes next to each other.
newbie
Activity: 28
Merit: 0
my paper clip trick on my powersupply is unstable, I put electrical tape over it (just that part of the connector it covers maybe 5 pins in a row) but it doesn't hold the paper clip down forever, it becomes less effective and the paper clip is able to move just the slightest to turn the power supply off


how do other people deal with this? Its just a minor annoyance because the block erupter blade reboots so quickly and gets back to work

You need a paper clip with a thicker diameter. I'm not sure what you mean by it covers 5 pins, mine is connected to 2 pins. Get a paper clip with wider diameter ends and tape it securely in place. Only cover the area where the paper clip is. Tape is cheap, don't spare it. Also it might help if you cut the paper clip down to an inch or an inch and a half.
hero member
Activity: 546
Merit: 500
my paper clip trick on my powersupply is unstable, I put electrical tape over it (just that part of the connector it covers maybe 5 pins in a row) but it doesn't hold the paper clip down forever, it becomes less effective and the paper clip is able to move just the slightest to turn the power supply off


how do other people deal with this? Its just a minor annoyance because the block erupter blade reboots so quickly and gets back to work
newbie
Activity: 19
Merit: 0
Here's my proxy command and notice I do not use user/password in the command so I can use only one proxy for 2 or more blades, each configured with its worker username and password:

nohup python mining_proxy.py -o stratum.btcguild.com -gp 8332 -o eu-stratum.btcguild.com -gp 8332 > /dev/null 2>&1 &
Does the proxy support multiple getwork hosts at once? And how it manage them (switch, etc.)?

Only testing to see if that works. I put both btcguild stratum servers so if the first one goes down it should connect to the second one.

J/

Why do you use twice the same getwork port "8332" Shouldn't you be using a different one for the backup server?

No. He's specifying the port of the pools. Both of those servers both have the same pool.

But for the mining pool you use -p and for the miners you use -gp. Did I miss something?
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
Here's my proxy command and notice I do not use user/password in the command so I can use only one proxy for 2 or more blades, each configured with its worker username and password:

nohup python mining_proxy.py -o stratum.btcguild.com -gp 8332 -o eu-stratum.btcguild.com -gp 8332 > /dev/null 2>&1 &
Does the proxy support multiple getwork hosts at once? And how it manage them (switch, etc.)?

Only testing to see if that works. I put both btcguild stratum servers so if the first one goes down it should connect to the second one.

J/

Why do you use twice the same getwork port "8332" Shouldn't you be using a different one for the backup server?

No. He's specifying the port of the pools. Both of those servers both have the same pool.
newbie
Activity: 19
Merit: 0
Here's my proxy command and notice I do not use user/password in the command so I can use only one proxy for 2 or more blades, each configured with its worker username and password:

nohup python mining_proxy.py -o stratum.btcguild.com -gp 8332 -o eu-stratum.btcguild.com -gp 8332 > /dev/null 2>&1 &
Does the proxy support multiple getwork hosts at once? And how it manage them (switch, etc.)?

Only testing to see if that works. I put both btcguild stratum servers so if the first one goes down it should connect to the second one.

J/

Why do you use twice the same getwork port "8332" Shouldn't you be using a different one for the backup server?
hero member
Activity: 518
Merit: 500
BTC < > INR & USD
Hi guys,
Blades have 2 pin female connectors for fans. I have only 3-pin Arctic Cooling F12 fans. How to connect these to 2 pins? On eBay I only found 1 auction in USA (I am in Europe) to adapters like this one: http://www.ebay.co.uk/itm/YAD2P-3pin-to-2pin-converter-adapter-/270681240944?pt=US_Computer_Case_Fans&hash=item3f05dbf570#shId
Any other idea (or link to Europe shop with parts) how to make them working nicely without cutting wires? Smiley

Don't connect it directly to the board. You end up simply passing the voltage required for the fans through the power module of the blade. As it is, the power module heats up. This is un-necessary.
Connect it to the PSU or to a fan controller (fan controller powers all the 6 fans using a single molex connector). See the OP or my setup on page 15 of this post.!
full member
Activity: 189
Merit: 100
Cant you connect them directly to your psu? Otherwise just search 3pin 2pin molex

example

http://www.caseking.de/shop/catalog/Kabel/Adapter/Luefter-Kabel/Adapter/Luefter-Adapterkabel-2-Pin-zu-3-Pin-Molex::14590.html

They should be available in your country.