Author

Topic: ANTMINER S3+ Discussion and Support Thread - page 412. (Read 710164 times)

hero member
Activity: 539
Merit: 500
Batch 3 is shipping.

2014-07-05 12:26:34
full member
Activity: 150
Merit: 100
Oh boy!
ok - I did reboot of my S3, one blade totally disappeared and the second one hashes only at 50%.. donw know what to do now. I removed and readded the ribbon cables from control module to blades - with no help, still 1/2 of first blade KO, 2nd blade KO full (not even LED indication)
legendary
Activity: 1789
Merit: 2535
Goonies never say die.
Well the S3's destroyed my Thermaltake 600W PSUs which had previously been powering cubes without any issues. They ran fine with them for about 30 minutes although cables were getting pretty hot, not 100% sure why it killed them yet. One PSU went peacefully, the other gave a nice fireworks display.  Shocked    Ended up using a Corsair RM1000 to power both and they have been running pretty good since, with no hot cables.  Grin

For the past few days one S3 was only avging 380GHs and showed no 'x' and everything looked fine but after a reboot it kicked it somewhat back in gear. Currently around 430GHs avg now. The other has been running fine avging 440GHs. No overclocking attempts at this point.
Thanks for replying, I'm hoping some more will share stories.

Which model thermaltake psu was that? You used it for only one unit?

This is the main reason I am on the search for a quality PSU which can handle the proper power on the 12V rail. I'm worried about using split pci-e cables because 24/7 operation and hot cables doesn't always end up good Sad Problem for me searching is the amount of PCI-e cables that actually come with most sub 1000w psu. I might end up getting a handful of the molex to PCI-e adapters Sad


Thermaltake TR2-600NL2NC
https://www.thermaltakeusa.com/products-model_Specification.aspx?id=C_00002032

I had 1 powering each S3. I initially tried using the split cable with both PCIx connections, but ended up using the split cable to power 1 connection on the S3 and using an adapter to convert 2x LP4s to a PCIx and used that as the 2nd connection - this may have been a mistake but my intent was to balance out the heating of the cables, which was a bigger issue using the split cable. The RM1000 has been running fine and the cables are cold (and flat)
legendary
Activity: 1789
Merit: 2535
Goonies never say die.
Well the S3's destroyed my Thermaltake 600W PSUs which had previously been powering cubes without any issues. They ran fine with them for about 30 minutes although cables were getting pretty hot, not 100% sure why it killed them yet. One PSU went peacefully, the other gave a nice fireworks display.  Shocked    Ended up using a Corsair RM1000 to power both and they have been running pretty good since, with no hot cables.  Grin

For the past few days one S3 was only avging 380GHs and showed no 'x' and everything looked fine but after a reboot it kicked it somewhat back in gear. Currently around 430GHs avg now. The other has been running fine avging 440GHs. No overclocking attempts at this point.


Where you using the 600W for running both? If so it would have been to much power draw for the power supply to handle. The S3 that is having issues it might be good to try re-flashing/updating the firmware.

One 600W per S3, I wouldn't attempt to power 2 on a 600W - the mathematics just don't work out.  Cheesy
Didn't realize there was a firmware update already but I will give this a try, thanks!
full member
Activity: 210
Merit: 100
Well the S3's destroyed my Thermaltake 600W PSUs which had previously been powering cubes without any issues. They ran fine with them for about 30 minutes although cables were getting pretty hot, not 100% sure why it killed them yet. One PSU went peacefully, the other gave a nice fireworks display.  Shocked    Ended up using a Corsair RM1000 to power both and they have been running pretty good since, with no hot cables.  Grin

For the past few days one S3 was only avging 380GHs and showed no 'x' and everything looked fine but after a reboot it kicked it somewhat back in gear. Currently around 430GHs avg now. The other has been running fine avging 440GHs. No overclocking attempts at this point.
Thanks for replying, I'm hoping some more will share stories.

Which model thermaltake psu was that? You used it for only one unit?

This is the main reason I am on the search for a quality PSU which can handle the proper power on the 12V rail. I'm worried about using split pci-e cables because 24/7 operation and hot cables doesn't always end up good Sad Problem for me searching is the amount of PCI-e cables that actually come with most sub 1000w psu. I might end up getting a handful of the molex to PCI-e adapters Sad
hero member
Activity: 630
Merit: 501
Miner Setup And Reviews. WASP Rep.
Well the S3's destroyed my Thermaltake 600W PSUs which had previously been powering cubes without any issues. They ran fine with them for about 30 minutes although cables were getting pretty hot, not 100% sure why it killed them yet. One PSU went peacefully, the other gave a nice fireworks display.  Shocked    Ended up using a Corsair RM1000 to power both and they have been running pretty good since, with no hot cables.  Grin

For the past few days one S3 was only avging 380GHs and showed no 'x' and everything looked fine but after a reboot it kicked it somewhat back in gear. Currently around 430GHs avg now. The other has been running fine avging 440GHs. No overclocking attempts at this point.


Where you using the 600W for running both? If so it would have been to much power draw for the power supply to handle. The S3 that is having issues it might be good to try re-flashing/updating the firmware.
legendary
Activity: 1789
Merit: 2535
Goonies never say die.
Well the S3's destroyed my Thermaltake 600W PSUs which had previously been powering cubes without any issues. They ran fine with them for about 30 minutes although cables were getting pretty hot, not 100% sure why it killed them yet. One PSU went peacefully, the other gave a nice fireworks display.  Shocked    Ended up using a Corsair RM1000 to power both and they have been running pretty good since, with no hot cables.  Grin

For the past few days one S3 was only avging 380GHs and showed no 'x' and everything looked fine but after a reboot it kicked it somewhat back in gear. Currently around 430GHs avg now. The other has been running fine avging 440GHs. No overclocking attempts at this point.
full member
Activity: 210
Merit: 100
What power supplies are you guys using to power your units?
full member
Activity: 150
Merit: 100
Oh boy!
Thank you for the tip - I will try it later today and definetly post results here. Wish me luck.. damn !
hero member
Activity: 616
Merit: 500
Can anyone tell me what to do when Miner Status page shows that BLADE 1 - 1 chip running, all other dead maybe?

Blade 2 ok

Tried to change power supplies, no luck Sad any help?
I had a similar issue on one of the S3s that arrived today.  One of the blades (2nd one) would not show on the status page of the web interface.  I took the cover off, pushed all the connectors of the 2 cables between the controller and the hashing boards into their sockets, and that seems to have rectified it (at least for now).  Maybe there is some workmanship/quality issue with these cables/connectors.  (see my post a bit earlier on this thread).

Good luck
full member
Activity: 150
Merit: 100
Oh boy!
Yeah it could be that. Will check asap
newbie
Activity: 49
Merit: 0
both user interface and "hard reboot".

Do you mean restore factory settings?

Oh no, I didn't mean a reset.
It's just that many people confuse rebooting with restarting but you got it right.

If your miner always had this problem you could try to check for excessive use of thermal paste under the heatsink.
Members have reported mixed results after cleaning and reapplying thermal paste.
legendary
Activity: 1232
Merit: 1000


6 kgs computer game Huh Yeah xD


I just think it would have been easier for them to understand than trying to explain Bitcoin or using the word "
mining" but good luck.
sr. member
Activity: 294
Merit: 251
Guys please help.

Just received a SMS saying(i will translate it, im spanish):

UPS REF: xxxxxxxxxxxxxxxx

call 902888820 option 5 or email [email protected] with reference, full name, NIF and product description for Customs.

What the hell?HuhHuh?

Last status was:

Lugar    Fecha    Hora Local    Actividad
Mumbai, India    23/07/2014    11:35    Escaneo de llegada
Bangkok, Thailand    23/07/2014    8:42    Escaneo de salida
23/07/2014    7:17    Escaneo de llegada
Shenzhen, China    23/07/2014    5:39    Escaneo de salida
Shenzhen, China    22/07/2014    23:52    Escaneo de exportación
Shenzhen, China    21/07/2014    23:28    Escaneo de llegada
21/07/2014    23:20    Escaneo de salida
21/07/2014    22:09    Escaneo de origen
21/07/2014    15:38    Falta una id. fiscal o número de aplazamiento, es necesario para el despacho. Trabajamos para obtener esta información.
Shenzhen, China    21/07/2014    20:42    Escaneo de recogida
China    20/07/2014    4:06    Orden procesada: Lista para UPS


Im calling lets see what happens.....  Embarrassed Embarrassed Embarrassed

they are telling me that i have to describe the articles because they dont understand me. I told them they are electronic devices for mining bitcoins, and the girl didnt understand what it was.... i have to send an email explaining it.

ffs
I think I would have used the word "computer game" into your description


6 kgs computer game Huh Yeah xD
full member
Activity: 150
Merit: 100
Oh boy!
both user interface and "hard reboot".

Do you mean restore factory settings?
newbie
Activity: 49
Merit: 0
Tried many times. It does it from start.

Just to be clear, did you reboot via the user interface?


full member
Activity: 150
Merit: 100
Oh boy!
Tried many times. It does it from start.
newbie
Activity: 49
Merit: 0
Can anyone tell me what to do when Miner Status page shows that BLADE 1 - 1 chip running, all other dead maybe?

Blade 2 ok

Tried to change power supplies, no luck Sad any help?

Try doing a reboot.
full member
Activity: 150
Merit: 100
Oh boy!
Can anyone tell me what to do when Miner Status page shows that BLADE 1 - 1 chip running, all other dead maybe?

Blade 2 ok

Tried to change power supplies, no luck Sad any help?
legendary
Activity: 1232
Merit: 1000
Guys please help.

Just received a SMS saying(i will translate it, im spanish):

UPS REF: xxxxxxxxxxxxxxxx

call 902888820 option 5 or email [email protected] with reference, full name, NIF and product description for Customs.

What the hell?HuhHuh?

Last status was:

Lugar    Fecha    Hora Local    Actividad
Mumbai, India    23/07/2014    11:35    Escaneo de llegada
Bangkok, Thailand    23/07/2014    8:42    Escaneo de salida
23/07/2014    7:17    Escaneo de llegada
Shenzhen, China    23/07/2014    5:39    Escaneo de salida
Shenzhen, China    22/07/2014    23:52    Escaneo de exportación
Shenzhen, China    21/07/2014    23:28    Escaneo de llegada
21/07/2014    23:20    Escaneo de salida
21/07/2014    22:09    Escaneo de origen
21/07/2014    15:38    Falta una id. fiscal o número de aplazamiento, es necesario para el despacho. Trabajamos para obtener esta información.
Shenzhen, China    21/07/2014    20:42    Escaneo de recogida
China    20/07/2014    4:06    Orden procesada: Lista para UPS


Im calling lets see what happens.....  Embarrassed Embarrassed Embarrassed

they are telling me that i have to describe the articles because they dont understand me. I told them they are electronic devices for mining bitcoins, and the girl didnt understand what it was.... i have to send an email explaining it.

ffs
I think I would have used the word "computer game" into your description