Pages:
Author

Topic: BITMAIN Antminer S1 support and OverClocking thread - page 3. (Read 144978 times)

newbie
Activity: 15
Merit: 0
Update 20.9

Seems that 412.50 MHz is too much, 2 chips went offline and 406.25 MHz seems stable... All the hassle for just ~3GH/s... well you win some you lose some...

e: HW error rate seems to be around 0.25% ... Not bad at all...

http://i58.tinypic.com/5p2c6s.jpg

newbie
Activity: 15
Merit: 0

#406
#option 'freq_value'    '6002' #406M
#option 'chip_freq'     '406.25'
#option 'timeout'       '35'






Thanks, I tried to push the miner to 425MHz but 2 chips failed immidiately, or reported that they do not work. So I setteled with your settings 406MHz and so far it seems stable with temps @ 24C and 25C, ambient 17C / hw= 0.22% ...

Would really like to know what is 410Mhz and 415Mhz...

edit:

Actually I found it on one page as follows

chip_freq timeout freq_value(s)
  37.50 373 0583, 0b87
  39.06 358 0c07
  40.62 344 0603, 0c87
  42.19 331 0d07
  43.75 320 0683, 0d87
  45.31 308 0e07
  46.88 298 0703, 0e87
  48.44 289 0f07
  50.00 280 0783, 0f87
  51.56 271 1007
  53.12 263 0803, 1087
  54.69 256 1107
  56.25 248 0883, 1187
  57.81 242 1207
  59.38 235 0903, 1287
  60.94 229 1307
  62.50 224 0983, 1387, 4983, 5387
  64.06 218 1407, 5407
  65.62 213 0a03, 1487, 4a03, 5487
  67.19 208 1507, 5507
  68.75 203 0a83, 1587, 4a83, 5587
  70.31 199 1607, 5607
  71.88 194 0b03, 1687, 4b03, 5687
  73.44 190 1707, 5707
  75.00 186 0582, 0b83, 0b86, 1787, 4b83, 5787
  76.56 182 5807
  78.12 179 0c06, 4c03, 5887
  79.69 175 5907
  81.25 172 0602, 0c86, 4c83, 5987
  82.81 169 5a07
  84.38 165 0d06, 4d03, 5a87
  85.94 162 5b07
  87.50 160 0682, 0d86, 4d83, 5b87
  89.06 157 5c07
  90.62 154 0e06, 4e03, 5c87
  92.19 151 5d07
  93.75 149 0702, 0e86, 4e83, 5d87
  95.31 146 5e07
  96.88 144 0f06, 4f03, 5e87
  98.44 142 5f07
 100.00 140 0782, 0f86, 4f83, 5f87
 101.56 137 6007
 103.12 135 1006, 5003, 6087
 104.69 133 6107
 106.25 131 0802, 1086, 5083, 6187
 107.81 129 6207
 109.38 128 1106, 5103, 6287
 110.94 126 6307
 112.50 124 0882, 1186, 5183, 6387
 114.06 122 6407
 115.62 121 1206, 5203, 6487
 117.19 119 6507
 118.75 117 0902, 1286, 5283, 6587
 120.31 116 6607
 121.88 114 1306, 5303, 6687
 123.44 113 6707
 125.00 112 0982, 1386, 4982, 5383, 5386, 6787
 128.12 109 1406, 5406
 131.25 106 0a02, 1486, 4a02, 5486
 134.38 104 1506, 5506
 137.50 101 0a82, 1586, 4a82, 5586
 140.62  99 1606, 5606
 143.75  97 0b02, 1686, 4b02, 5686
 146.88  95 1706, 5706
 150.00  93 0581, 0b82, 0b85, 1786, 4b82, 5786
 153.12  91 5806
 156.25  89 0c05, 4c02, 5886
 159.38  87 5906
 162.50  86 0601, 0c85, 4c82, 5986
 165.62  84 5a06
 168.75  82 0d05, 4d02, 5a86
 171.88  81 5b06
 175.00  80 0681, 0d85, 4d82, 5b86
 178.12  78 5c06
 181.25  77 0e05, 4e02, 5c86
 184.38  75 5d06
 187.50  74 0701, 0e85, 4e82, 5d86
 190.62  73 5e06
 193.75  72 0f05, 4f02, 5e86
 196.88  71 5f06
 200.00  70 0781, 0f85, 4f82, 5f86
 203.12  68 6006
 206.25  67 1005, 5002, 6086
 209.38  66 6106
 212.50  65 0801, 1085, 5082, 6186
 215.62  64 6206
 218.75  64 1105, 5102, 6286
 221.88  63 6306
 225.00  62 0881, 1185, 5182, 6386
 228.12  61 6406
 231.25  60 1205, 5202, 6486
 234.38  59 6506
 237.50  58 0901, 1285, 5282, 6586
 240.62  58 6606
 243.75  57 1305, 5302, 6686
 246.88  56 6706
 250.00  56 0981, 1385, 4981, 5382, 5385, 6786
 256.25  54 1405, 5405
 262.50  53 0a01, 1485, 4a01, 5485
 268.75  52 1505, 5505
 275.00  50 0a81, 1585, 4a81, 5585
 281.25  49 1605, 5605
 287.50  48 0b01, 1685, 4b01, 5685
 293.75  47 1705, 5705
 300.00  46 0580, 0b81, 0b84, 1785, 4b81, 5785
 306.25  45 5805
 312.50  44 0c04, 4c01, 5885
 318.75  43 5905
 325.00  43 0600, 0c84, 4c81, 5985
 331.25  42 5a05
 337.50  41 0d04, 4d01, 5a85
 343.75  40 5b05
 350.00  40 0680, 0d84, 4d81, 5b85
 356.25  39 5c05
 362.50  38 0e04, 4e01, 5c85
 368.75  37 5d05
 375.00  37 0700, 0e84, 4e81, 5d85
 381.25  36 5e05
 387.50  36 0f04, 4f01, 5e85
 393.75  35 5f05
 400.00  35 0780, 0f84, 4f81, 5f85
 406.25  34 6005
 412.50  33 1004, 5001, 6085
 418.75  33 6105
 425.00  32 0800, 1084, 5081, 6185
 431.25  32 6205
 437.50  32 1104, 5101, 6285
 443.75  31 6305
 450.00  31 0880, 1184, 5181, 6385
 456.25  30 6405
 462.50  30 1204, 5201, 6485
 468.75  29 6505
 475.00  29 0900, 1284, 5281, 6585
 481.25  29 6605
 487.50  28 1304, 5301, 6685
 493.75  28 6705
 500.00  28 0980, 1384, 4980, 5381, 5384, 6785
 512.50  27 1404, 5404
 525.00  26 0a00, 1484, 4a00, 5484
 537.50  26 1504, 5504
 550.00  25 0a80, 1584, 4a80, 5584
 562.50  24 1604, 5604
 575.00  24 0b00, 1684, 4b00, 5684
 587.50  23 1704, 5704
 600.00  23 0b80, 1784, 4b80, 5784
 612.50  22 5804
 625.00  22 4c00, 5884
 637.50  21 5904
 650.00  21 4c80, 5984
 662.50  21 5a04
 675.00  20 4d00, 5a84
 687.50  20 5b04
 700.00  20 4d80, 5b84
 712.50  19 5c04
 725.00  19 4e00, 5c84
 737.50  18 5d04
 750.00  18 4e80, 5d84
 762.50  18 5e04
 775.00  18 4f00, 5e84
 787.50  17 5f04
 800.00  17 4f80, 5f84
 812.50  17 6004
 825.00  16 5000, 6084
 837.50  16 6104
 850.00  16 5080, 6184
 862.50  16 6204
 875.00  16 5100, 6284
 887.50  15 6304
 900.00  15 5180, 6384
 912.50  15 6404
 925.00  15 5200, 6484
 937.50  14 6504
 950.00  14 5280, 6584
 962.50  14 6604
 975.00  14 5300, 6684
 987.50  14 6704
1000.00  14 5380, 6784
sr. member
Activity: 308
Merit: 250
Decentralize your hashing - p2pool - Norgz Pool
Hi everybody (my 1st post)

I have an Antminer S1 and I tried to find the right frequency settings for over 400MHz clocking. I have a seriously modded Antminer pushing at ~205GH/s with an HW error rate of 0.025%.

I know the 400 setting is

option 'freq_value'   '4f81'        #400M
option 'chip_freq'     '400'
option 'timeout'       '35'

but I am looking to overclock to eg. 410MHz --> 425MHz --> 450MHz

Could someone tell what the freq_values for these settings would be.

Much appriciated



#406
#option 'freq_value'    '6002' #406M
#option 'chip_freq'     '406.25'
#option 'timeout'       '35'




newbie
Activity: 15
Merit: 0
Hi everybody (my 1st post)

I have an Antminer S1 and I tried to find the right frequency settings for over 400MHz clocking. I have a seriously modded Antminer pushing at ~205GH/s with an HW error rate of 0.025%.

I know the 400 setting is

option 'freq_value'   '4f81'        #400M
option 'chip_freq'     '400'
option 'timeout'       '35'

but I am looking to overclock to eg. 410MHz --> 425MHz --> 450MHz

Could someone tell what the freq_values for these settings would be.

Much appriciated

http://i61.tinypic.com/2ypaywl.jpg
newbie
Activity: 8
Merit: 0
hi, I have several S1's and if needed, can always get them to reset to 192.168.1.99... I just recently took one outside and blew it with air to get some cat hair out of it and when I went to hook it up, it would not mine, so I tried to do the reset button every which way and it won't reset... for some reason the orange light won't come on the  network plug... I have tried multiple network cables, ports, psu's and no matter what can't get the thing to reset... I am at my wits end and don't know what to do... it just won't reset and turn the orange light on - its like it needs to be shocked or reset, but the reset button and holding it down and restarting isn't doing the trick, any suggestions?
hero member
Activity: 798
Merit: 1000
Sorry if this was already asked, I just couldn't find it anywhere.  But here's my question:  Are you able to clock the Antminer S1 at a frequency that isn't something like  350, 375, 400, etc.  Something in-between those numbers.  I recently received an Antminer S1 and had it clocked to 375 because my PSU doesn't have enough watts on the 12 volt rail to go to 400.  I want to get the most out of my miner before it becomes non-profitable though, so can I clock it to something like 380 or 390?  I think I remember someone doing 389.9 because it ran better than 400, not too sure.  Thanks and sorry if this is a stupid question, I'm new to Antminers a bit.

Here you go:

Code:
        option 'freq_value'    '5f05'  #393.75M
        option 'chip_freq'     '393.75'
        option 'timeout'       '36'

        #option 'freq_value'    '5e85'  #387.5M
        #option 'chip_freq'     '387.5'
        #option 'timeout'       '37'
full member
Activity: 173
Merit: 101
Sorry if this was already asked, I just couldn't find it anywhere.  But here's my question:  Are you able to clock the Antminer S1 at a frequency that isn't something like  350, 375, 400, etc.  Something in-between those numbers.  I recently received an Antminer S1 and had it clocked to 375 because my PSU doesn't have enough watts on the 12 volt rail to go to 400.  I want to get the most out of my miner before it becomes non-profitable though, so can I clock it to something like 380 or 390?  I think I remember someone doing 389.9 because it ran better than 400, not too sure.  Thanks and sorry if this is a stupid question, I'm new to Antminers a bit.
hero member
Activity: 784
Merit: 504
I have some small heatsinks that would fit the DCDC, do you think it would make a small difference in efficiency and DCDC stability?

it should help with keeping them cooler and running with less errors. go ahead and do it. I've got them on all of mine and it runs 406mhz all day long.

Any thought if that would help the DC-DC issue the early S3's have? cool em down and maybe you can pull a bit more juice from them?


I don't think just cooling down the DC-DC controller will bailout the Antminer S3 problem.
It may increase the hashrate a little bit more or help to hash it with more stability.
I'm designing a setup to cool the DC-DC controller extremely down with heatsink and water cooling pipe setup.
No high expectations but checking whether it can hold at 504Ghs or 478Ghs or atleast stable at 441Ghs.
Will try it at S1 before moving to S3. Now I'm searching for some small copper pipes, do anyone know a source to get it?
hero member
Activity: 784
Merit: 504
Hello tell me the reason for my fan speed does not reset.  Thats when cold then immediately grows And does not reset when the temperature is 35 or 45 shows in 3720 within 3480  Thank you  if daste answer.

Downclock you Ant and restart your miner after shutting off for 10 minutes.
I mean do a power cycle. Then check whether the fan speeds now.
Now set your Ant S1 at stock clock and check fan speed after a restart.
If fan responds properly, clock to previous frequency and check the fans now.
member
Activity: 61
Merit: 10
Hello tell me the reason for my fan speed does not reset.  Thats when cold then immediately grows And does not reset when the temperature is 35 or 45 shows in 3720 within 3480  Thank you  if daste answer.
sr. member
Activity: 308
Merit: 250
Decentralize your hashing - p2pool - Norgz Pool
I have some small heatsinks that would fit the DCDC, do you think it would make a small difference in efficiency and DCDC stability?

it should help with keeping them cooler and running with less errors. go ahead and do it. I've got them on all of mine and it runs 406mhz all day long.

Any thought if that would help the DC-DC issue the early S3's have? cool em down and maybe you can pull a bit more juice from them?

possibly, Bitmain tend to under spec those parts to save money. I considered sourcing some higher rated ones to overclock the s1 further, it's getting to the limit of my electronics knowledge though.
Put it this way, it couldn't hurt them lol
sr. member
Activity: 467
Merit: 250
I have some small heatsinks that would fit the DCDC, do you think it would make a small difference in efficiency and DCDC stability?

it should help with keeping them cooler and running with less errors. go ahead and do it. I've got them on all of mine and it runs 406mhz all day long.

Any thought if that would help the DC-DC issue the early S3's have? cool em down and maybe you can pull a bit more juice from them?
sr. member
Activity: 308
Merit: 250
Decentralize your hashing - p2pool - Norgz Pool
I have some small heatsinks that would fit the DCDC, do you think it would make a small difference in efficiency and DCDC stability?

it should help with keeping them cooler and running with less errors. go ahead and do it. I've got them on all of mine and it runs 406mhz all day long.
hero member
Activity: 714
Merit: 500
I have some small heatsinks that would fit the DCDC, do you think it would make a small difference in efficiency and DCDC stability?
full member
Activity: 146
Merit: 100
What would be the most optimal settings for the S2 with a 1200W Psu and excellent ambient cooling?

~ Luc
sr. member
Activity: 308
Merit: 250
Decentralize your hashing - p2pool - Norgz Pool
Has anyone ever tried clocking an S1 beyond 400 MHz? Bitmain docs give settings info to clock up to 500 MHz. If anyone has tried let me know the power draw and hash rate and error rates you were getting. Thanks.

As per datasheet 400M is very much possible. But the issue is with HWE%, it will be huge.
Also the huge power consumption will not make it run profitably.
Further, the DC-DC voltage converters will not be able to handle that much and will overheat and fail.
No where heard anyone did it successfully for a prolonged period. If you are trying it don't forget to update the result.
406mhz at 41 degrees. Hw 0.7% for a few days now
That's great. You got a special S1.
My S1 will give 0.7% HWE much before that.
At stock clock itself my temperatures are at 40-45.
It is a special little unit that's for sure. In return I've looked after it with nice big second fan and heatsinks all round.
hero member
Activity: 784
Merit: 504
Has anyone ever tried clocking an S1 beyond 400 MHz? Bitmain docs give settings info to clock up to 500 MHz. If anyone has tried let me know the power draw and hash rate and error rates you were getting. Thanks.

As per datasheet 400M is very much possible. But the issue is with HWE%, it will be huge.
Also the huge power consumption will not make it run profitably.
Further, the DC-DC voltage converters will not be able to handle that much and will overheat and fail.
No where heard anyone did it successfully for a prolonged period. If you are trying it don't forget to update the result.
406mhz at 41 degrees. Hw 0.7% for a few days now
That's great. You got a special S1.
My S1 will give 0.7% HWE much before that.
At stock clock itself my temperatures are at 40-45.
sr. member
Activity: 308
Merit: 250
Decentralize your hashing - p2pool - Norgz Pool
Has anyone ever tried clocking an S1 beyond 400 MHz? Bitmain docs give settings info to clock up to 500 MHz. If anyone has tried let me know the power draw and hash rate and error rates you were getting. Thanks.

As per datasheet 400M is very much possible. But the issue is with HWE%, it will be huge.
Also the huge power consumption will not make it run profitably.
Further, the DC-DC voltage converters will not be able to handle that much and will overheat and fail.
No where heard anyone did it successfully for a prolonged period. If you are trying it don't forget to update the result.
406mhz at 41 degrees. Hw 0.7% for a few days now
hero member
Activity: 784
Merit: 504
Has anyone ever tried clocking an S1 beyond 400 MHz? Bitmain docs give settings info to clock up to 500 MHz. If anyone has tried let me know the power draw and hash rate and error rates you were getting. Thanks.

As per datasheet 400M is very much possible. But the issue is with HWE%, it will be huge.
Also the huge power consumption will not make it run profitably.
Further, the DC-DC voltage converters will not be able to handle that much and will overheat and fail.
No where heard anyone did it successfully for a prolonged period. If you are trying it don't forget to update the result.
newbie
Activity: 27
Merit: 0
I had some trouble with an S2 recently. Fixed it with an off the shelf Beaglebone Black.

https://bitcointalksearch.org/topic/revive-a-dead-antminer-s2-with-beaglebone-black-rev-c-off-the-shelf-671625
Pages: