Here is a datasheet for a typical remote diode temperature management/fan control IC.
http://www.ti.com/lit/ds/symlink/lm96063.pdfNote: "The LM96063 is remote diode temperature sensors with integrated fan control that includes remote diode sensing. The LM96063 accurately measures: (1) its own temperature and (2) the temperature of a diode- connected transistor, such as a 2N3904, or a
thermal diode commonly found on Computer Processors, Graphics Processor Units (GPU) and other
ASIC's."
These type of devices typically integrate with an on die thermal diode.
On the issue of BRM46x thermal design constraints, the spec says 125 C. Not 100 C, not 105 C. Looking at the data sheet, it looks like the device temperature is reported via the PMBus and may also be subject to configuration via a configuration file:
"This product is designed with a digital control circuit. The control circuit uses a configuration file which determines the functionality and performance of the product. The Electrical Specification table shows parameter values of functionality and performance with the default configuration file, unless otherwise specified. The default configuration file is designed to fit most application needs with focus on high efficiency. If different characteristics are required it is possible to change the configuration file to optimize certain performance characteristics. Note that current sharing operation requires changed configuration file. See application notes AN307 for further information."
Is anyone having problems with Neptune's shutting down due to thermal issues or is this yet more FUD being spread by haters and envious ne'er do wells towards KNC ?