I mean seriously, more than two units of avalon mini's is impossible in one room. They are like hot stones!
These chips cannot be over 375mhz for sure..
I was thinking of leading the hot air from the units with one of these aluminium "tubes" anyone have experience doing this? I have a window slightly open, but the room is still heating up, and the units default at 350mhz running on 50dgrs.. (i dont really care about the heat, its more the noise and the power draw i care about, and by releasing hot air, keeping them cool, should increase speed and lower heat..).
something like this maybe?
http://www.directindustry.com/prod/yang-chiuan-industrial-co-ltd/aluminum-coated-galvanised-steel-fabric-hoses-88137-894785.htmlAluminium coated galvanised steel fabric hose. 130dgr+ ok.
For a batch 3 avalon, I used the following parts:
http://www.homedepot.com/p/Master-Flow-14-in-x-6-in-to-8-in-Universal-Register-Box-with-Flange-RBF14X6X8/100154377Obviously, find a register box that would fit your needs. This 14x6 barely fit the batch 3 after I straightened out the flanges (tear apart welds and unfold) to act as an air funnel that the avalon sits in.
http://www.ehydroponics.com/ecoplus-inline-duct-booster.htmlChoose the correct size booster to fit the other side of the register. I connected the register box directly to the booster, and used duct tape to seal it. I didn't seal the register box to the avalon, so I figured a booster would help the exhaust go the right way, instead of out the unsealed part.
http://www.ehydroponics.com/deflecto-metallic-duct-4-x-25.htmlChoose the correct size duct to match the booster. I simply used duct tape and some bungee cords to exhaust the hot air outside. I chose this instead of the insulated kind because it would be easier to work with (insulation needs respirators and special washing of clothing after).
These are the parts I used because they were all available in B&M stores, as opposed to having to order online and wait. I had just gotten my avalon 1.5 days before and the uninsulated room I had put it in was already 10F warmer than outside and still rising. After this, the room is at most 2F hotter than outside. I debated using it as intake, but I worried about taking outside air directly without a filter / water drain. As an exhaust, the walls act as a big filter.