Pages:
Author

Topic: [Guide] Dogie's Comprehensive ASICMiner Blade Setup - page 12. (Read 580761 times)

newbie
Activity: 50
Merit: 0
You mean at config page?

Current Server: 192.168.1.1:8332
Chip: OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO

Yes, they are always OOOOOOO
legendary
Activity: 1946
Merit: 1035
I think that the Chip: OOOO/xxxx information line is only set once during power on self test, and if chips fail afterwards (or are back to normal), it won't be updated.

Am I the only one who experienced this? (V1 blades here)
newbie
Activity: 50
Merit: 0
If you refresh during a hang, do the chips still read O or are some of them X'd?

Do you mean, when I click "refresh" button at config page during a hang, if stats readings stay at 00000?

Oh well, mostly I think, I have to close cmd window and restart mining_proxy .bat file in order to make stats readings get higher.

What is X'd? Sorry I dont know what that means.
hero member
Activity: 784
Merit: 1004
Glow Stick Dance!
Is that a terrible idea?  If so, why?

No, if you have a monitoring solution for each Blade that doesn't rely on the pool

Otherwise you'll always be wondering if that 12.5% percent drop is just variance or faulty Blade.

Thanks!  I'm not too worried about variance from my Blades.  They're pretty much rock-solid and never go down.
legendary
Activity: 3374
Merit: 1859
Curmudgeonly hardware guy
If you refresh during a hang, do the chips still read O or are some of them X'd?
newbie
Activity: 50
Merit: 0
Here?   3.29V
It's have be working about 10hrs without hang.
If hangs again I'll let you know what was the reading.

Edit: It hangs again after 12hrs, voltage reading was 3.28v
legendary
Activity: 3374
Merit: 1859
Curmudgeonly hardware guy
What's the voltage on the 3.3V lines read? Is it steady at 3.3V, or does it sag a bit - especially during a "hang"?
legendary
Activity: 1946
Merit: 1035
I had filled DNS with 8.8.8.8 and 8.8.4.4, but now I realized that must be the router IP on primary DNS and 8.8.8.8 (or other) in secondary DNS. I do not know if that have anything to see with the problem.

Except the very unlikely case where you would be using local names from your local DNS instead of using IP addresses or Internet names, it should not be the cause of any problem
newbie
Activity: 50
Merit: 0
Hi there.

My blade blew the new 10amp fuse the same day I bought it. I contacted the seller and told him I'll have to send it back. He told me that he was sorry for the issue, and ask me if I want to return it for replace or refund, in deed he gave me the address to return it. Also wanted to know the cost of return shipping in order to refund that amount to me. Well, that was very polite and gentle.

I have not answered him yet. I'm kind of doubtful. I would like to try the blade just a week more so I changed the fuse again, and if it works flawless, then I would keep it.

But now it works a litlle wierd some times. I mean after 8-10 hours of working seem to be freezed. All counters of stats were reset to zero. The ".bat" file of minig proxy stay just waiting or listening for, like freezed, the lines on cmd window dont move. So, I have to restart it manually to make it work again. I happened like 4 or 5 times and I have used it 4 days only.

I had filled DNS with 8.8.8.8 and 8.8.4.4, but now I realized that must be the router IP on primary DNS and 8.8.8.8 (or other) in secondary DNS. I do not know if that have anything to see with the problem.

What do you suggest to me? Keep it and try few more days, or just return it and get a new one.

Thanks in advance.-
legendary
Activity: 1946
Merit: 1035
Is that a terrible idea?  If so, why?

No, if you have a monitoring solution for each Blade that doesn't rely on the pool

Otherwise you'll always be wondering if that 12.5% percent drop is just variance or faulty Blade.
hero member
Activity: 784
Merit: 1004
Glow Stick Dance!
So I got tired of my 8 Blades cluttering up my stats with 8 individual workers and assigned them all the same worker name.  I figured that it was good enough for my 70 USB Erupters and Bitfury boards, why not do it with my Blades

Is that a terrible idea?  If so, why?
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
I am having trouble getting my blades up and running in a data center.
They have no DNS.  Does anybody know what I should put in the two fields for primary and secondary DNS?
Not sure about ports either.
Any help appreciated.

They must have a router, that's the primary DNS. Secondary can potentially be left blank or 8.8.8.8. Port is the port you connect to the blade on, ie 192.168.1.254:8000
legendary
Activity: 1593
Merit: 1004
I am having trouble getting my blades up and running in a data center.
They have no DNS.  Does anybody know what I should put in the two fields for primary and secondary DNS?
Not sure about ports either.
Any help appreciated.
legendary
Activity: 3374
Merit: 1859
Curmudgeonly hardware guy
I thought about suggesting a simple bridge, but if a fuse is blown then it might have been something fairly serious caused it, in which case bridging without a fusible line could cause something to overcurrent and explode.

Good thing that didn't happen, good to hear it seems to be working.
newbie
Activity: 50
Merit: 0
Looks to be the case, yeah. The R fuse is actually 8A, pretty sure; the blue-board blades came with 10A fuses. There ought be no problem using that current rating. If you don't have any SMD fuses handy, test with a 10A automotive blade fuse. If that works, it works; if the test fuse blows, there's something further wrong with the board.
Oh well, I will look for them.
There is an electronic supplier store near to my house.
Thanks for your help.

EDIT:
I made a bridge with a paper clip on fuse terminals and guess what?

I powered it on!
All leds were blinking and could access to the config menu 192.168.1.254:8000 LOL
I'll buy a 10A fuse tomorrow early in the morning.  Grin

Thanks again.-
legendary
Activity: 3374
Merit: 1859
Curmudgeonly hardware guy
Looks to be the case, yeah. The R fuse is actually 8A, pretty sure; the blue-board blades came with 10A fuses. There ought be no problem using that current rating. If you don't have any SMD fuses handy, test with a 10A automotive blade fuse. If that works, it works; if the test fuse blows, there's something further wrong with the board.
newbie
Activity: 50
Merit: 0
You read 12V at the fuse? Which side of the fuse? Measure for voltage across it: - on one side, + on the other, and you should see awful close to zero volts. If you see anything other than zero volts, the fuse is blown.

Did you check for voltage at the 3.3V output? Measure for 3.3V across C286, for 12V across C165, and for 1.05V across C288.

These are the readings I took:

C165 = -2.2mV (Orange).......... should be 12V
C286 = 1.3mV (Yellow).......... should be 3.3V
C288 = 0 (Ligth Blue).......... should be 1.05V
F1 = -12.12v (Pink).......... should be 0V
Power Pins Input Conector = 12.13v (Pink) it's OK

F1 = fuse right? So it's blown.
I must replace it first.
How much Amps can it handle?
10A@12V?

After replacing the F1 fuse; readings (C165, C286, C288) should back to normal?
Or something else could be blown or broken?

Very thankful for your time/help. Smiley

legendary
Activity: 3374
Merit: 1859
Curmudgeonly hardware guy
You read 12V at the fuse? Which side of the fuse? Measure for voltage across it: - on one side, + on the other, and you should see awful close to zero volts. If you see anything other than zero volts, the fuse is blown.

Did you check for voltage at the 3.3V output? Measure for 3.3V across C286, for 12V across C165, and for 1.05V across C288.
newbie
Activity: 50
Merit: 0
Hi there.

I need a little help.
I bought this BEB 10.7GHs Rev2 at amazon on 16-nov. It was delivered on time in USA but I live in Venezuela. So It was stored a couple of weeks at the currier company I use to import stuff to my country with other things I bought. I received it here in Venezuela just today.

It was factory sealed and packed properly with protective foam. Nice.

But it seems to be DOA.
It does nothing when I power it on, no warms up, no ethernet leds blinking.

I try these online guides but there was no success.
https://bitcointalksearch.org/topic/asicminer-blade-sales-temporarily-out-of-stock-204030
https://bitcointalksearch.org/topic/guide-dogies-comprehensive-asicminer-blade-setup-205369
https://bitcointalksearch.org/topic/asicminer-block-erupter-blade-psu-cooling-solutions-288787

I also check the power pins on the board with a multimeter and it's ok.
It shows 12 Vdc with polarirty in same direction showed in the board, so is not a power supply problem.


I also checked F1 box which seems to be a fuse location, it shows -12Vdc keeping polarity in same direction that power pins.

Although I can not read at a glance, thanks to macro photo I can do it now.

Reset: I guess these works like jumpers of any motherboard.
1-2 normal
2-3 factory reset

Debug: I guess this is a conection port for diagnostics with 7-segment display or something like that.
Tx: Transmission
Rx: Reception
GND: ground

MCLR: memory clear
+3.3v: obvious
PGD: no idea
PGC: no idea

F1: fuse box with a resistor I guess.

X12, X13, X14: Fan conections?

I emailed the seller but still no answer.
I can sent it back to the seller in the USA via fedex if necessary in order to get a replace.
But if I missed some step to get it work, please let me know.

Any sugestion to make this thing work properly?

Thanks in advance.-
DKO
newbie
Activity: 13
Merit: 0
Ah, you're running them both out of a single batch file instead of straight from multiple consoles. Good to hear you got it figured out.

Cheers. Yeah I should have mentioned that.
Pages:
Jump to: