Could someone PLEASE help, again:
I have an issue with a unit where it wasn't connecting to Wifi At all I have my others setup correctly so it was no issue beforehand. But for whatever reason this specific unit wouldnt detect any wifi so I decided to press the reset button on the controller board. Now I cannot detect it at all. I've tried to do the reset procedure a couple times and its still the same result. I have it connected to a switch that is connected to the router. All the other units are fine, its just this one unit giving me trouble...any ideas or suggestions?
Reset button is what caused this to happen, I cannot connect to it at all even if its directly plugged into my computer. I do see activity on the controler with it being plugged into a switch that is plugged into the router. This device had worked okay before. Someone on IRC said at this point the only thing I could probably do is JTAG but bitmain says "not possible for the avg user" If that is what I need to do, fine, lets do it, but could someone walk me through that?
I've tried to:
Reset miner as FAQ states.
Do the full 30-30-30 power cycle with the reset button pressed down
SSH into the miner with the default .99 IP
SSH into the miner while connected via ethernet to the default .99 IP
Unplug the device.
Download a decent IP scanner, famatech's IP Scan will do.
Display your IP address details, and write them down. 192.168.x.x mask 255.255.x.x, Default Gateway, DNS.
For the purpose I will assume your PC's IP is 192.168.1.11 but just replace it with yours
Set your PC's IP address to be 192.168.1.11
Set your PC's IP Subnet Mask or NetMask to 255.255.254.0
Run the IP scanner and take note of all addresses
Plug in the Ant to the switch and wait for the lights on the ethernet port to come on.
Run the IP scanner and find the new address that was not there before.
Connect to the new address and set the WAN IP address to one that has the same first three set of digits as the IP address your PC, for example
192.168.1.x where digits in bold are the same and x is a number that is not on the list of address in the IP scanner.
Apply the changes on the Ant miner, the display will never, ever get past the point where the wait circle keeps on spinning, just leave it as it is.
Set your PC's IP details back to the original that you wrote down.
Power the Ant off, wait 5 seconds, then power the ant back on.
Wait until the lights on the ethernet port to come on.
Now connect to the ant using the browser on the IP address that you set on the ant.