for the early morning problem.. my log says dsl connection was (re)established
12.06.2012, 04:31
- so I dont think that was the problem
miner was startet (not regarding the login data) with that one:
java -cp /home/wolf/btcminer/ZtexBTCMiner-120417.jar BTCMiner -f ztex_ufm1_15y1.ihx -host http://mmpool.bitparking.com:15098 -u vv01f -p testpw -b http://de.btcguild.com:8332 vv01f_fpga testpwd -b http://eu.ozco.in:8332 accnumber testpw -l /home/wolf/btcminer/fpga.log -bl /home/wolf/btcminer/fpga-submitted.log -m c -oh 0.08
resulting finally in full stop with error msg
2012-06-12T05:03:48: Stopped thread for bus 001-0
after some problem with pool data / a string (not sure how to read that properly):
2012-06-12T04:59:28: 001-0: ztex_ufm1_15y1-04A36DE0AA-3: Error: Read timed out: Disabling URL http://mmpool.bitparking.com:15098 for 60s
2012-06-12T04:59:32: 001-0: ztex_ufm1_15y1-04A36DE0AA-1: Error: Read timed out: Disabling URL http://mmpool.bitparking.com:15098 for 60s
2012-06-12T05:00:10: 001-0: ztex_ufm1_15y1-04A36E0711-4: Error: Read timed out: Disabling URL http://mmpool.bitparking.com:15098 for 60s
2012-06-12T05:00:16: 001-0: ztex_ufm1_15y1-04A36E0711-2: Error: Read timed out: Disabling URL http://mmpool.bitparking.com:15098 for 60s
2012-06-12T05:00:30: 001-0: ztex_ufm1_15y1-04A36DE0AA-4: Error: Read timed out: Disabling URL http://mmpool.bitparking.com:15098 for 60s
2012-06-12T05:00:57: 001-0: ztex_ufm1_15y1-04A36E0711-1: Error: Read timed out: Disabling URL http://mmpool.bitparking.com:15098 for 60s
2012-06-12T05:01:23: 001-0: ztex_ufm1_15y1-04A36E0711-3: Error: Read timed out: Disabling URL http://mmpool.bitparking.com:15098 for 60s
2012-06-12T05:01:40: 001-0: ztex_ufm1_15y1-04A36DE0AA-1: Error: Read timed out: Disabling URL http://mmpool.bitparking.com:15098 for 60s
2012-06-12T05:01:56: 001-0: ztex_ufm1_15y1-04A36E0711-4: Error: Invalid length of string: Disabling device
2012-06-12T05:01:56: 001-0: ztex_ufm1_15y1-04A36E0711-2: Error: Invalid length of string: Disabling device
2012-06-12T05:01:57: 001-0: ztex_ufm1_15y1-04A36DE0AA-3: Error: Invalid length of string: Disabling device
2012-06-12T05:01:57: 001-0: ztex_ufm1_15y1-04A36DE0AA-4: Error: Invalid length of string: Disabling device
2012-06-12T05:02:11: 001-0: ztex_ufm1_15y1-04A36E0711-1: Error: Invalid length of string: Disabling device
2012-06-12T05:02:41: 001-0: ztex_ufm1_15y1-04A36E0711-3: Error: Read timed out: Disabling URL http://mmpool.bitparking.com:15098 for 60s
2012-06-12T05:02:46: 001-0: ztex_ufm1_15y1-04A36DE0AA-1: Error: Invalid length of string: Disabling device
2012-06-12T05:02:59: Warning: Invalid length of string
2012-06-12T05:03:29: 001-0: ztex_ufm1_15y1-04A36DE0AA-1: Error: Invalid length of string: Device disabled since 2012-06-12T05:02:46
2012-06-12T05:03:29: 001-0: ztex_ufm1_15y1-04A36DE0AA-2: Error: Hash rate drop of 10,0% detect. This may be caused by overheating. FPGA is shut down to prevent damage. 50.0: Device disabled since 2012-06-11T06:43:14
2012-06-12T05:03:29: 001-0: ztex_ufm1_15y1-04A36DE0AA-3: Error: Invalid length of string: Device disabled since 2012-06-12T05:01:57
2012-06-12T05:03:29: 001-0: ztex_ufm1_15y1-04A36DE0AA-4: Error: Invalid length of string: Device disabled since 2012-06-12T05:01:57
2012-06-12T05:03:29: 001-0: ztex_ufm1_15y1-04A36E0711-1: Error: Invalid length of string: Device disabled since 2012-06-12T05:02:11
2012-06-12T05:03:29: 001-0: ztex_ufm1_15y1-04A36E0711-2: Error: Invalid length of string: Device disabled since 2012-06-12T05:01:56
2012-06-12T05:03:29: 001-0: ztex_ufm1_15y1-04A36E0711-3: f=216,00MHz, errorRate=0,11%, maxErrorRate=1,23%, hashRate=215,8MH/s, submitted 10 new nonces, luckFactor=0,91
2012-06-12T05:03:29: 001-0: ztex_ufm1_15y1-04A36E0711-4: Error: Invalid length of string: Device disabled since 2012-06-12T05:01:56
2012-06-12T05:03:29: 001-0: poll loop time: 236ms (USB: 11ms network: 225ms) getwork time: 362ms submit time: 407ms
2012-06-12T05:03:29: 001-0: Warning: 3 overflows occured. This is usually caused by a slow network connection.
2012-06-12T05:03:29: Total hash rate: 215,8 MH/s
2012-06-12T05:03:29: Total submitted hash rate: 195,7 MH/s
2012-06-12T05:03:29: --------
2012-06-12T05:03:48: 001-0: ztex_ufm1_15y1-04A36E0711-3: Error: Invalid length of string: Disabling device
full log for that run:
Log 4 BTCMiner failing on some string error - it will expire in ~30d.
Thanks for the hint with c-command while runtime.. it seems I didnt read that help properly.
But for now I see no lasting effekt. Just randomly the # of 2nd fpga on the problematic board (also slowing down) changes, right now #4 is slowed down to 200 MHz and #3 I also saw disabled at first try until manual q-command.
For some time the hash rate will go up, but I fear it having bad impact done to often.
No offence, I will not change the setup to your firmware until ztex says its Ok for same reasons I will not set -oh above 0.1 - just prevent further damage he has nothing to do with. Instead I will try to keep at least 3 cores of that board running stable until Friday.