SP can you please provide a link to some rackmount ears for the SP10?

There are so many options, I just want some that work on the SP10 without going through the trial-and-error of ordering the wrong ones a few times.

PM me if you are worried that it may seem you are "endorsing" a product.

It's custom made. Please contacts [email protected]
We'll add it as a product in our store soon.

The ears we can provide are only the front side mounting ears and you will need to add some additional mounting element to the rear side.
 
We are planning to solve it for the SP30 and to provide ears for both sides that may fit most if not all racks.
hero member
Activity: 700
Merit: 504
Run a Bitcoin node.
SP can you please provide a link to some rackmount ears for the SP10?

There are so many options, I just want some that work on the SP10 without going through the trial-and-error of ordering the wrong ones a few times.

PM me if you are worried that it may seem you are "endorsing" a product.
hero member
Activity: 658
Merit: 500
When ambient is at an acceptable temperature, you just need ventilation. It doesn't matter how much heat you put into the air if you can simply substitute that air with ambient temp air.

You think if even is +40C?
Yep.

It doesn't matter how fast you wee into a cup, if I keep replacing your cup with an empty cup, you'll never fill it.

not quite a correct analogy.

Ventilation does not prevent turbulence. Air can be travel inefficiently that hot air got suck back into the miner .
You need to build a ducting system right at the rack. Thats the only way to control direction of air. Remember folks, you need ventilation and air direction control to be effective.

You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....

Right, you expect the room layout to work with you. Stop making empty suggestion like this pls.

Build a ducting system from the rack to wherever the vent is.


Or, or, or, maybe this... don't put a mining farm in a room ill equipped for mining.

I choose my flats almost solely based on their suitability to mining and cooling. Proper Planning Prevents Piss Poor Performance!

So why dont you suggest that?

Ppl dont usually have luxury to choose their mining room. Not to mention residential house's rooms arent built to take 1+ kw of constant heat.
sr. member
Activity: 434
Merit: 250
When ambient is at an acceptable temperature, you just need ventilation. It doesn't matter how much heat you put into the air if you can simply substitute that air with ambient temp air.

You think if even is +40C?
Yep.

It doesn't matter how fast you wee into a cup, if I keep replacing your cup with an empty cup, you'll never fill it.

not quite a correct analogy.

Ventilation does not prevent turbulence. Air can be travel inefficiently that hot air got suck back into the miner .
You need to build a ducting system right at the rack. Thats the only way to control direction of air. Remember folks, you need ventilation and air direction control to be effective.

You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....

Right, you expect the room layout to work with you. Stop making empty suggestion like this pls.

Build a ducting system from the rack to wherever the vent is.


Or, or, or, maybe this... don't put a mining farm in a room ill equipped for mining.

I choose my flats almost solely based on their suitability to mining and cooling. Proper Planning Prevents Piss Poor Performance!

The 6 Ps!

P'ing all over the thread.  Cheesy
legendary
Activity: 1904
Merit: 1007
When ambient is at an acceptable temperature, you just need ventilation. It doesn't matter how much heat you put into the air if you can simply substitute that air with ambient temp air.

You think if even is +40C?
Yep.

It doesn't matter how fast you wee into a cup, if I keep replacing your cup with an empty cup, you'll never fill it.

not quite a correct analogy.

Ventilation does not prevent turbulence. Air can be travel inefficiently that hot air got suck back into the miner .
You need to build a ducting system right at the rack. Thats the only way to control direction of air. Remember folks, you need ventilation and air direction control to be effective.

You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....

Right, you expect the room layout to work with you. Stop making empty suggestion like this pls.

Build a ducting system from the rack to wherever the vent is.


Or, or, or, maybe this... don't put a mining farm in a room ill equipped for mining.

I choose my flats almost solely based on their suitability to mining and cooling. Proper Planning Prevents Piss Poor Performance!

The 6 Ps!
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
When ambient is at an acceptable temperature, you just need ventilation. It doesn't matter how much heat you put into the air if you can simply substitute that air with ambient temp air.

You think if even is +40C?
Yep.

It doesn't matter how fast you wee into a cup, if I keep replacing your cup with an empty cup, you'll never fill it.

not quite a correct analogy.

Ventilation does not prevent turbulence. Air can be travel inefficiently that hot air got suck back into the miner .
You need to build a ducting system right at the rack. Thats the only way to control direction of air. Remember folks, you need ventilation and air direction control to be effective.

You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....

Right, you expect the room layout to work with you. Stop making empty suggestion like this pls.

Build a ducting system from the rack to wherever the vent is.


Or, or, or, maybe this... don't put a mining farm in a room ill equipped for mining.

I choose my flats almost solely based on their suitability to mining and cooling. Proper Planning Prevents Piss Poor Performance!
hero member
Activity: 658
Merit: 500
You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....
I have my miners in my garage and this will be the first hot weekend of the summer. I'm hoping that by opening my garage door a few times a day I can recycle the air. Its north facing and thats where the cool wind comes from. If that doesnt work I have a 12000 BTC portable AC unit ready to go. Would rather not use it though.

Exactly! For the vast majority of the year I cool my miners passively, with 0W. In the summer I simply add a 60W fan to help aid the ventilation to ambient. Its 40x more efficient than using AC.

I hope noone can just blindly follow your suggestion.

There is a word called BTU. You dont just add 60w fan to cool.... you-dont-know how many kW.

Anyone looking to cool a mining room, needs to do proper calculation of the amount of air volume you need to move. With the dimension of the vent you have, you can calculate the air velocity required for that volume, then you can pick a fan.

Fan can use from 50w to 1000w.
hero member
Activity: 658
Merit: 500
When ambient is at an acceptable temperature, you just need ventilation. It doesn't matter how much heat you put into the air if you can simply substitute that air with ambient temp air.

You think if even is +40C?
Yep.

It doesn't matter how fast you wee into a cup, if I keep replacing your cup with an empty cup, you'll never fill it.

not quite a correct analogy.

Ventilation does not prevent turbulence. Air can be travel inefficiently that hot air got suck back into the miner .
You need to build a ducting system right at the rack. Thats the only way to control direction of air. Remember folks, you need ventilation and air direction control to be effective.

You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....

Right, you expect the room layout to work with you. Stop making empty suggestion like this pls.

Build a ducting system from the rack to wherever the vent is.

newbie
Activity: 48
Merit: 0
I ordered 6 more units yesterday afternoon, tracking number appeared in my email this morning!

SP is on top of it, every unit I've received has worked flawlessly out of the box.    Top quality product and team!

 Grin



legendary
Activity: 1904
Merit: 1007
If that doesnt work I have a 12000 BTC portable AC unit ready to go.

That must be the most expensive AC unit in the world!

I'm guessing he meant BTU ... LOL

Too much mining Smiley
newbie
Activity: 27
Merit: 0
If that doesnt work I have a 12000 BTC portable AC unit ready to go.

That must be the most expensive AC unit in the world!

I'm guessing he meant BTU ... LOL
legendary
Activity: 1904
Merit: 1007
You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....
I have my miners in my garage and this will be the first hot weekend of the summer. I'm hoping that by opening my garage door a few times a day I can recycle the air. Its north facing and thats where the cool wind comes from. If that doesnt work I have a 12000 BTC portable AC unit ready to go. Would rather not use it though.

Exactly! For the vast majority of the year I cool my miners passively, with 0W. In the summer I simply add a 60W fan to help aid the ventilation to ambient. Its 40x more efficient than using AC.

That's my plan too! Kudos.
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....
I have my miners in my garage and this will be the first hot weekend of the summer. I'm hoping that by opening my garage door a few times a day I can recycle the air. Its north facing and thats where the cool wind comes from. If that doesnt work I have a 12000 BTC portable AC unit ready to go. Would rather not use it though.

Exactly! For the vast majority of the year I cool my miners passively, with 0W. In the summer I simply add a 60W fan to help aid the ventilation to ambient. Its 40x more efficient than using AC.
legendary
Activity: 3878
Merit: 1193
If that doesnt work I have a 12000 BTC portable AC unit ready to go.

That must be the most expensive AC unit in the world!
hero member
Activity: 728
Merit: 500
When ambient is at an acceptable temperature, you just need ventilation. It doesn't matter how much heat you put into the air if you can simply substitute that air with ambient temp air.

You think if even is +40C?
Yep.

It doesn't matter how fast you wee into a cup, if I keep replacing your cup with an empty cup, you'll never fill it.

not quite a correct analogy.

Ventilation does not prevent turbulence. Air can be travel inefficiently that hot air got suck back into the miner .
You need to build a ducting system right at the rack. Thats the only way to control direction of air. Remember folks, you need ventilation and air direction control to be effective.

You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....
I have my miners in my garage and this will be the first hot weekend of the summer. I'm hoping that by opening my garage door a few times a day I can recycle the air. Its north facing and thats where the cool wind comes from. If that doesnt work I have a 12000 BTC portable AC unit ready to go. Would rather not use it though.
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
When ambient is at an acceptable temperature, you just need ventilation. It doesn't matter how much heat you put into the air if you can simply substitute that air with ambient temp air.

You think if even is +40C?
Yep.

It doesn't matter how fast you wee into a cup, if I keep replacing your cup with an empty cup, you'll never fill it.

not quite a correct analogy.

Ventilation does not prevent turbulence. Air can be travel inefficiently that hot air got suck back into the miner .
You need to build a ducting system right at the rack. Thats the only way to control direction of air. Remember folks, you need ventilation and air direction control to be effective.

You don't if you have floor to ceiling double ended ventilation. Ie a door on one side and a door on the other....
donator
Activity: 1414
Merit: 1051
Spondoolies, Beam & DAGlabs
Hello,

Is the 10% discount offer for people who purchased from other manufacturers still available for SP30 August 2nd Batch?


For the SP30: Yes, contact [email protected]
It's not available for the SP10 anymore

Thanks,

I see there are also no bundle offers anymore is that right?

No. We tried to simplify the web site and offerings.
newbie
Activity: 27
Merit: 0
You are referring to the S1 right? Because right now the S2 is worse priced than the SP10.

S2 is 1 TH/s @ $1844 (just use one of the countless $400 off coupons lying around).

and receive a box with rattley broken stuff inside  Cheesy no thank you.

I have 2 SP10's + 1 S2 running in my garage.  You are 100% right in that I had to re-seat each S2 hashing board before plugging it in.  But now, it works like a charm.  The S2 does draw 50% more power than do SP10's.

HOWEVER, the S2's are super-quiet.  SP10's are so loud that even if I really really wanted to, I could not add one to my collection.  Which basically, leaves me with the S2 as the only option on the market.  You cannot underestimate the value of quiet.  I can overcome the rattley stuff inside.  Noise is very difficult to overcome.
sr. member
Activity: 462
Merit: 250
Hello,

Is the 10% discount offer for people who purchased from other manufacturers still available for SP30 August 2nd Batch?


For the SP30: Yes, contact [email protected]
It's not available for the SP10 anymore

Thanks,

I see there are also no bundle offers anymore is that right?
sr. member
Activity: 434
Merit: 250
You are referring to the S1 right? Because right now the S2 is worse priced than the SP10.

S2 is 1 TH/s @ $1844 (just use one of the countless $400 off coupons lying around).

and receive a box with rattley broken stuff inside  Cheesy no thank you.
Jump to: