Pages:
Author

Topic: ANTMINER C1 Discussion and Support Thread - page 65. (Read 129130 times)

sr. member
Activity: 366
Merit: 250
November 29, 2014, 01:20:40 PM
still not reply from bitmain

emailed them my order id like they asked this morning around 2-3am pst.


My c1 paperweight is so cool. It has a theoretical hashing of 1ths............except my unit is DOA...

What's the deal bitmain?

Losing 5$/day on this unit. I know it has not been long for them to respond so I will remain patient.

curious to see how these people sort this issue out.

This is the most beautiful paperweight i have ever seen.
legendary
Activity: 1540
Merit: 1001
November 29, 2014, 12:04:00 PM
It shows as already on cgminer 4.6.1, and when I try to upgrade it to the current firmware, I get this:

What system version does it show its on at the moment? Should look like a date.

Quote
- Navigate to System -> Overview and look at "File System Version".

Wed Nov 26 10:27:37 CST 2014


M
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
November 29, 2014, 11:53:30 AM
It shows as already on cgminer 4.6.1, and when I try to upgrade it to the current firmware, I get this:

What system version does it show its on at the moment? Should look like a date.

Quote
- Navigate to System -> Overview and look at "File System Version".
legendary
Activity: 1540
Merit: 1001
November 29, 2014, 11:47:09 AM
Got my C1.  Hooked it up.  All is well.

I'm surprised that it behaves like an S2, not an S3.

Including the poor results with p2pool. Sad  It shows as already on cgminer 4.6.1, and when I try to upgrade it to the current firmware, I get this:

Code:
runme.sh exe
Content-type: text/html
















(and more)

So far I'm not impressed. Sad

Fortunately it works fine with Eligius.

M
legendary
Activity: 1167
Merit: 1009
November 29, 2014, 08:48:41 AM
So no one is going to comment on the several users having X's in their ASIC status area and having under powered units?

Several users being you, and one other person who fixed his. What exactly do you want people to do about it?

Chinesesavoir and Mindtrip both had X's in their ASIC status area. And when you have those X's your (guaranteed) hashing power drops. And after changing the voltage, which I've already done to 740, the X goes away but eventually comes back. Now with 2 X's for even less hashing power. What if I wanted to sell in the future and as the specifications indicate 10008GH/s and the unit can't even get to that, then I'm pretty much screwed. I'm just wondering how every is getting 1000TH/s with no problems and I have 6 of them struggling to keep above 950GH/s. I guess I'm just expecting more support and attention like I'm use to with other companies I have purchased from. 

Are you here as a mascot/cheerleader for Bitmaintech or really here for support purposes?


So here is an update I was only able to perform the volt mod on 1 unit as the other is in my office and I won't have access to physically power cycle it until monday but it appears over volting the one i have access to has eliminated the X issue after 12 hours of solid run time and I am now running over the guaranteed hash rate. I will test the other unit again in the next few days with the same voltage and see if this is a good fix for the issue. You have to remember from the factory these are overclocked from what and S3+ is running 225 vs 250 so there is a good chance they need slightly higher voltage to maintain that overclock for long run times. I have spent time reading through the spec sheet on the chips and I suspect a 10 to 20 step over volt will not do any harm to the chips long term and will help any users with random X errors. I hope this helps those members with the issue
legendary
Activity: 1274
Merit: 1000
Personal text my ass....
November 29, 2014, 08:25:23 AM
So no one is going to comment on the several users having X's in their ASIC status area and having under powered units?

Several users being you, and one other person who fixed his. What exactly do you want people to do about it?

Chinesesavoir and Mindtrip both had X's in their ASIC status area. And when you have those X's your (guaranteed) hashing power drops. And after changing the voltage, which I've already done to 740, the X goes away but eventually comes back. Now with 2 X's for even less hashing power. What if I wanted to sell in the future and as the specifications indicate 10008GH/s and the unit can't even get to that, then I'm pretty much screwed. I'm just wondering how every is getting 1000TH/s with no problems and I have 6 of them struggling to keep above 950GH/s. I guess I'm just expecting more support and attention like I'm use to with other companies I have purchased from. 

Are you here as a mascot/cheerleader for Bitmaintech or really here for support purposes?
sr. member
Activity: 366
Merit: 250
November 29, 2014, 06:15:28 AM
its def the two boards i emailed them and they asked for my order id and havent heard back.

pump and radiator works find when plugged into 3 and 4 boards


p.s. now one of my 6 s3's is showin 0 gh/s poolside but the pool is showing 2.7th/s which is if all 6 were running.. i have no clue why it the pool would show an s3 not hashing but then see in my total hash it is?Huh?


legendary
Activity: 1666
Merit: 1185
dogiecoin.com
November 29, 2014, 04:58:05 AM
miner is burning hot to touch on hose fittigs... guessing pump failed and thermal shutdown etc.
sells like a burnt board in the room too... damint please nooooo
going to give 20m cooldown and try reboot.

dead dead dead :/ Huh Cool

so how do i fix this headache novelty device or get it swapped with the warranty center in Colorado for some s3's

Make sure its not mining any more when you boot up, or on for the fan but not mining. I would have left it several hours to cool off passively as its not designed to operate at that temp (chips are fine but nearby components might not like the heat). Buy a new pump, locally if you can't wait. Careful trying to move anything, that tubing will be much more rubbery and more prone to pulling off.

Once you know what / if anything is dead, send an email to [email protected] for the C1.
sr. member
Activity: 366
Merit: 250
November 29, 2014, 04:41:20 AM
Just did another re-test....

If you are looking at it from the fan side...

The right two board seem to be toast..

The fan and pumps seems to be going okay when i plug them into 3+4 but 1+2 are dead....

lets how bitmain twerks  Tongue

just trying to get them to agree to swap for 3 s3's Roll Eyes
hero member
Activity: 658
Merit: 500
November 29, 2014, 04:39:19 AM
Received my C1 today - here's a quick summary.

- The B2 (with cooling kit) arrived with all required pieces, plus an extra hose fitting, extra O-ring, and two extra clamps.
- The fan/pump power harness was the 2nd gen version that connects directly to the PSU or PCI cable.  I checked it with an Ohm meter and visually - it's wired correctly and the connections appear to be well protected with heat-shrink tubing.
- There were a couple of small plastic 'spirals' from thread cutting inside the pump tank that were easily rinsed out.  There were also water droplets in the tank - signs of wet testing.


The miner, fans, pump, and EVGA 1000W PSU are whisper quiet.  The idling fan on an Asus AMD R9-290 reference card is at least twice as loud as this is.  I have a pair of S3+ and a Dell 750W server PSU in the kitchen with the C1 - it's very difficult to hear the C1.

It's running between .995 and 1.4 TH/s locally, and between .992 and 1.02 TH/s pool-side at stock speed/voltage with no Xs after 1 hour of running.

Also, Spiceminer's Ant Viewer picked up the C1 same as the S3s.

Bitmain and Syscooling - nice job!

Indeed! just dont come back here soon ok?
hero member
Activity: 658
Merit: 500
November 29, 2014, 04:38:41 AM
my c1 just died.................


psu fan still working psu seems find...

pump and everythhing are dead on c1...........


miner is burning hot to touch on hose fittigs...

guessing pump failed and thermal shutdown etc.

sells like a burnt board in the room too...

damint please nooooo

going to give 20m cooldown and try reboot.

dead dead dead :/ Huh Cool

so how do i fix this headache novelty device or get it swapped with the warranty center in Colorado for some s3's

i was about to say .... enjoy your cheap watercooling POS kit .....  Grin
sr. member
Activity: 366
Merit: 250
November 29, 2014, 03:46:47 AM
my c1 just died.................


psu fan still working psu seems find...

pump and everythhing are dead on c1...........


miner is burning hot to touch on hose fittigs...

guessing pump failed and thermal shutdown etc.

sells like a burnt board in the room too...

damint please nooooo

going to give 20m cooldown and try reboot.

dead dead dead :/ Huh Cool

so how do i fix this headache novelty device or get it swapped with the warranty center in Colorado for some s3's
legendary
Activity: 1652
Merit: 1067
Christian Antkow
November 29, 2014, 03:19:39 AM
 Is it relatively straightforward to undervolt a C1 to ~550W ? If so, what sort of hash rate could we expect at that wattage ? Thinking of picking up a couple fo' shiggles and tinkering purposes.
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
November 29, 2014, 03:08:03 AM
So no one is going to comment on the several users having X's in their ASIC status area and having under powered units?

Several users being you, and one other person who fixed his. What exactly do you want people to do about it?
legendary
Activity: 1274
Merit: 1000
Personal text my ass....
November 29, 2014, 02:17:38 AM
So no one is going to comment on the several users having X's in their ASIC status area and having under powered units?
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
November 29, 2014, 01:19:36 AM
after following my c1 all around the city i finally got it.

Hook up and hashing at 1ths smooth as butter.

whats the best site to post pictures too now? Roll Eyes

imgur.com (less advertising and far faster than Flickr)


imgur compresses everything and doesn't handle large file sizes.
hero member
Activity: 895
Merit: 504
November 28, 2014, 09:34:22 PM
Well,no one considered like this before,you could try and see whether the temperature is higher than 8 fans for 4 C1s or 3 fans for 1 C1.Now all the wiring harness is new,could be plugged into board directly.
[/quote]

How long is the warranty on the SC-C2 pump? Not sure if I should buy it, because if the pump fails all 4 C1 will be idle.
full member
Activity: 154
Merit: 100
November 28, 2014, 08:49:48 PM
if i run this

http://shop.syscooling.com/goods.php?id=46

it says it can sustain 4 of the c1's

can i integrate the stock 3 fan w pump into the same or separate loop totaling 6 units ran by 11 fans?

also does the 8 fan kit come with the updated harness? If so do you have to plug it into 1 or 2 c1s?
Well,no one considered like this before,you could try and see whether the temperature is higher than 8 fans for 4 C1s or 3 fans for 1 C1.Now all the wiring harness is new,could be plugged into board directly.
full member
Activity: 154
Merit: 100
November 28, 2014, 08:33:20 PM
im too lazy to post pics atm but i will...

I'm in the middle of preparing to transfer to something with more power.

Im also ordering two more b3 c1's tonight to hookup to the 8 fan unit.

i kind of wish i didnt get the radiator because i dont know what to do with this.

If 8 fans cools 4 c1's would this 3 fan cool 2?

if i can plug 2 into this 3 fan that would be perfect
I am sure you'd better not do this,effect of 8 fans is not simply added,just like 3 fans support one machine rather than 2 fans.
legendary
Activity: 1274
Merit: 1000
Personal text my ass....
November 28, 2014, 06:32:56 PM
I got 2 Units on wednesday both seem to be underperforming from there guaranteed spec at stock clock and voltage. One will not take a single step overclock without throwing X I am going to spend some time tinering with voltage and clock speeds anyone have any feed back on voltage steps other than to go in steps of 10?

Yea, well this seems to be a problem here. Between me and my father we own 6 C1's and all of them have X's under the ASIC status area and ALL are underperforming. Apparently other users are having the same issue. If raising the voltage doesn't resolve the issue what are we supposed to do? Get an RMA and ship all these back to China? I think Bitmain needs to modify the hashing speed on these C1's. More like 950GH/s. I haven't seen 1000GH/s in a long time. Is there a support channel through the Bitmain site or something?

Pages: