Is there a way to set a 4th pool in the web interface?

You might use the more option field for this, just append 4th pool setting to your avalon options, such as

Quote
--real-quiet --avalon-auto -o stratum+tcp://stratum.btcguild.com:3333 -O ur_worker_name:123456

Didn't tried it, but it should work.  Why do you need 4th pool?
legendary
Activity: 1246
Merit: 1002
August 22, 2013, 12:56:49 PM
Is there a way to set a 4th pool in the web interface?
full member
Activity: 206
Merit: 100
August 22, 2013, 12:54:49 PM
anyone tried removing the rear panel for batch 1 and lowers temp?
I have removed for batch#3 and lowered temperature by 2C. The presure felt when keeping panel with the hand was pretty substantial. I'm sure that if the slots were larger and beveled on the inside too it would have been better.
You might give it a try, it's not even necessary to power down the machine if you're careful and don't mind back panel to lye captive by the power cord.

I cringe at the thought of one of those metal nuts bouncing onto the pdu board.

Neah, you'll just test PSU's short-circuit protection circuitry Smiley
hero member
Activity: 952
Merit: 502
SAPG Pre-Sale Live on Uniswap!
August 22, 2013, 10:46:17 AM
after 20h I have
[Device Hardware%] => 1.6749
Is this OK?
[Firmware Version] => 20130821

What clock speed?
--avalon-auto
start clock 350Mhz
legendary
Activity: 2450
Merit: 1002
August 22, 2013, 09:45:52 AM
after 20h I have
[Device Hardware%] => 1.6749
Is this OK?
[Firmware Version] => 20130821

What clock speed?
hero member
Activity: 952
Merit: 502
SAPG Pre-Sale Live on Uniswap!
August 22, 2013, 09:44:20 AM
after 20h I have
[Device Hardware%] => 1.6749
Is this OK?
[Firmware Version] => 20130821
E
full member
Activity: 234
Merit: 100
August 22, 2013, 12:05:55 AM
Uploaded new firmware
http://ck.kolivas.org/apps/cgminer/avalon/20130821/

contains cgminer 3.4.0 which only has slightly more in it than the last firmware since that was based on the preliminary 3.4.0 code

3.4.0 announce:
https://bitcointalksearch.org/topic/m.2978868


Code:
Human readable changelog:

- HW error % will show in the cgminer API log tab on the avalon web interface.

member
Activity: 90
Merit: 10
August 21, 2013, 11:31:23 PM
Uploaded new firmware
http://ck.kolivas.org/apps/cgminer/avalon/20130821/

contains cgminer 3.4.0 which only has slightly more in it than the last firmware since that was based on the preliminary 3.4.0 code

3.4.0 announce:
https://bitcointalksearch.org/topic/m.2978868


I'm running the 20130821 firmware on a 4-module batch 3 box, and my yellow LED (next to the green one) now flashes, on for a half-a-second, and off for a half-a-second over and over - still mining OK - but this yellow flashing is new - anyone else's also blinking with the 130821 firmware?
legendary
Activity: 966
Merit: 1000
August 21, 2013, 07:48:59 PM
anyone tried removing the rear panel for batch 1 and lowers temp?
I have removed for batch#3 and lowered temperature by 2C. The presure felt when keeping panel with the hand was pretty substantial. I'm sure that if the slots were larger and beveled on the inside too it would have been better.
You might give it a try, it's not even necessary to power down the machine if you're careful and don't mind back panel to lye captive by the power cord.

I cringe at the thought of one of those metal nuts bouncing onto the pdu board.


You can't grab 'em with a magnet either.  I guess they're zinc or something.
newbie
Activity: 13
Merit: 0
August 21, 2013, 05:13:33 PM
20130821 works fine, will see in next 12h
hero member
Activity: 952
Merit: 502
SAPG Pre-Sale Live on Uniswap!
August 21, 2013, 01:06:00 PM
Uploaded new firmware
http://ck.kolivas.org/apps/cgminer/avalon/20130821/

contains cgminer 3.4.0 which only has slightly more in it than the last firmware since that was based on the preliminary 3.4.0 code

3.4.0 announce:
https://bitcointalksearch.org/topic/m.2978868

thanks, will try Wink
legendary
Activity: 1246
Merit: 1002
August 21, 2013, 12:16:20 PM
anyone tried removing the rear panel for batch 1 and lowers temp?
I have removed for batch#3 and lowered temperature by 2C. The presure felt when keeping panel with the hand was pretty substantial. I'm sure that if the slots were larger and beveled on the inside too it would have been better.
You might give it a try, it's not even necessary to power down the machine if you're careful and don't mind back panel to lye captive by the power cord.

I cringe at the thought of one of those metal nuts bouncing onto the pdu board.
sr. member
Activity: 364
Merit: 250
August 21, 2013, 12:14:22 PM
Selling an Avalon in case anyone wants to add to the collection.

https://bitcointalksearch.org/topic/m.2979829
full member
Activity: 226
Merit: 100
August 21, 2013, 12:11:00 PM
i also removed it and i see good results! frequency is up since i have --avalon-auto Wink
full member
Activity: 206
Merit: 100
August 21, 2013, 10:49:19 AM
anyone tried removing the rear panel for batch 1 and lowers temp?
I have removed for batch#3 and lowered temperature by 2C. The presure felt when keeping panel with the hand was pretty substantial. I'm sure that if the slots were larger and beveled on the inside too it would have been better.
You might give it a try, it's not even necessary to power down the machine if you're careful and don't mind back panel to lye captive by the power cord.
sr. member
Activity: 294
Merit: 250
August 21, 2013, 08:03:59 AM
anyone tried removing the rear panel for batch 1 and lowers temp?
-ck
legendary
Activity: 4088
Merit: 1631
Ruu \o/
August 21, 2013, 07:28:46 AM
Uploaded new firmware
http://ck.kolivas.org/apps/cgminer/avalon/20130821/

contains cgminer 3.4.0 which only has slightly more in it than the last firmware since that was based on the preliminary 3.4.0 code

3.4.0 announce:
https://bitcointalksearch.org/topic/m.2978868
sr. member
Activity: 277
Merit: 254
August 21, 2013, 05:16:48 AM
So, I am running late Batch 2 with 20130703. Will flashing to the latest version increase hash rate?
Thanks!

The 20130818 firmware increased my speed by at least 1 GH/s consistently, so I'd say choose that one or later to flash.

Thanks. I went for 20130820 and I can confirm your measurements! It is +1GH on 3 module Batch 2 machine.
24 hours uptime with avg. 82.876 GH and it was 81.8 avg. before the update.
donator
Activity: 1218
Merit: 1079
Gerald Davis
August 20, 2013, 10:59:17 PM
Personally I am about to order one of these, as I am in your same boat (950W at the wall on a 910W PC Power & Cooling - hoping it doesn't fry with calculated 840W actual load, but 12V rail is still 12.2 so I think I'm good...) on my 4-module:

PSU are rated on DC load.  So a 910W PC P&C means it has a peak load of 910W DC.  If 90% efficient at 100% load that would mean 910W DC = 1,011W AC (910/0.9).

950W AC = 855W DC (950W*0.9)

I assumed 90% but you should look up efficiency curve for your PSU.  If you cant find one and it is an "80Plus" rated unit you can check the 80Plus website.  They have test which show efficiency at 100% load.
newbie
Activity: 31
Merit: 0
August 20, 2013, 10:48:46 PM
I have a batch 3 unit and replaced the PSU with one slightly too long to fit.

I'm running it now with the rear panel removed, and it actually runs about 5 degrees cooler than before.