Pages:
Author

Topic: BITMAIN Antminer S1 support and OverClocking thread - page 26. (Read 144980 times)

full member
Activity: 182
Merit: 100
I have my 2 antminers running with 1000watt nzxt psu and they do fine however i do not use high overclocks if you use 400 mhz or higher 500 tot 525 watt per device is needed minimal
Asic settings found on different topics:

mhz : 387.5
freq_value '5e85'
timeout 38

mhz :393.75
freq_value '5f05'
timeout 38

One miner still constant turns all the O into X after several hours of mining, i have no clue why this constant happens
The Hashrate seems to be according the specified range, but i am worried about this one

Power usage from the 387 setting seems to be 490watt

I got the following, with a i600 coolermaster

412 watt 191 GH/s 4e81 timeout 38  "375"  decimal 20097  ~1 hour HW=193

(http://www.mathsisfun.com/binary-decimal-hexadecimal-converter.html)

435 watt 192 GH/s 4f81 timeout 35 "400"   decimal 20353  ~1 hour HW=11,623



we need to know the relationship between the timeout and speed ??
full member
Activity: 230
Merit: 100
I'm selling my antminer on ebay:

http://r.ebay.com/6f6Y3a

Already overclocked to 192 GH/s for you.  I will accept BTC for cheaper.  Send me PM
full member
Activity: 210
Merit: 100
So a serious question,

What is the difference between 0780 and 4f81 in the overclock settings?

What if I change the frequency to 410?

Anyone tried?

0780 is in decimals 1920
4f81  is in decimals 20353

And what are these options in etc/config/cgminer?

config cgminer 'default'
   option chip_frequency '282'
   option miner_count '24'

sr. member
Activity: 252
Merit: 250
Hi
 do you have any advice how to split AntminerS1 hash power?
 For example 4*50 GHs?
 Is it possible?
thanks

You have edit the /etc/config/cgminer and /etc/init.d/cgminer to either load balance or round robin. I have it working with three pools but I do not have a fourth pool so I have never bothered to try.
sr. member
Activity: 588
Merit: 250
--bitmain-dev Set bitmain device (default: usb mode, other windows: COM1 or linux: /dev/bitmain-asic)

--bitmain-hwerror   Set bitmain device detect hardware error

--bitmain-auto      Adjust bitmain overclock frequency dynamically for best hashrate

--bitmain-cutoff Set bitmain overheat cut off temperature (default: 60)

--bitmain-fan Set fanspeed percentage for bitmain, single value or range (default: 20-100)

--bitmain-freq Set frequency range for bitmain-auto, single value or range

--bitmain-options Set bitmain options baud:miners:asic:timeout:freq

--bitmain-temp Set bitmain target temperature (default: 50)

None but --bitmain-options do anything, do they?
sr. member
Activity: 588
Merit: 250
Hi
 do you have any advice how to split AntminerS1 hash power?
 For example 4*50 GHs?
 Is it possible?
thanks

not possible.

You could do quotas, effectively splitting the hash power, as long as the pools are up and running.
full member
Activity: 365
Merit: 100
I was trying to use the 'Restore to default' setting in my ANTminer today and it restarted automatically like it was supposed to but it doesn't let me log in. I shows the black LuCi screen and then moves to a page cannot be loaded screen.


I am tried used the hard reset by jumping the wires but it does not work. Has anyone had the same problem?
full member
Activity: 147
Merit: 100
it is a interesting setup, but maybe try back the original hardware config, and compare temperatures, also try oc a little less than 400 like 393 as written in blog, maybe get out more mbtc/hour
hero member
Activity: 818
Merit: 508
All X's is firmware thing first time I saw it I freaked out.

If I did my math correct HW Error is .02 right now.

It's one day right now because I swapped the PSU out the yesterdayish.  Before same setup ran 5 days straight before i moved locations of the miners.  Moved them into the shop area from our hang out area.

I'm use to the x issue

HWI% =  (HW)/(HW + Diffa +Diffr + Diffs).  If my numbers are correct = (103,560)/(103,560 + 4,279,472 + 5632+0) = i get 2.37.  Am I wrong in my way of calculating hwi%?

Please tell me I am so I can clock my miner at 200

https://www.google.com/search?q=%28103%2C560%29%2F%28103%2C560+%2B+4%2C279%2C472+%2B+5632%2B0%29+%3D+&ie=utf-8&oe=utf-8&aq=t&rls=org.mozilla:en-US:official&client=firefox-a

you missed the multiplying by 100

http://cryptomining-blog.com/tag/hw-error-formula/
sr. member
Activity: 486
Merit: 262
rm -rf stupidity
So no testing above the 400 area with any major cooling upgrades?
full member
Activity: 230
Merit: 100
So does #375M actually work?  What kind of hash rate does it give?  What's the power usage like?

I'm getting 192 GH/s average with 375 and very low HW (less than 10 total /day).  Definitely recommend this setting as it stays quiet and cool, assuming you don't get many HW errors
full member
Activity: 182
Merit: 100
Hi
 do you have any advice how to split AntminerS1 hash power?
 For example 4*50 GHs?
 Is it possible?
thanks

not possible.

possible . i run on 4 pools for low variance ( with 2 ants )
sr. member
Activity: 294
Merit: 250
тσ ¢σιи σя иσт тσ ¢σιи?
All X's is firmware thing first time I saw it I freaked out.

If I did my math correct HW Error is .02 right now.

It's one day right now because I swapped the PSU out the yesterdayish.  Before same setup ran 5 days straight before i moved locations of the miners.  Moved them into the shop area from our hang out area.

I'm use to the x issue

HWI% =  (HW)/(HW + Diffa +Diffr + Diffs).  If my numbers are correct = (103,560)/(103,560 + 4,279,472 + 5632+0) = i get 2.37.  Am I wrong in my way of calculating hwi%?

Please tell me I am so I can clock my miner at 200

https://www.google.com/search?q=%28103%2C560%29%2F%28103%2C560+%2B+4%2C279%2C472+%2B+5632%2B0%29+%3D+&ie=utf-8&oe=utf-8&aq=t&rls=org.mozilla:en-US:official&client=firefox-a
hero member
Activity: 818
Merit: 508
All X's is firmware thing first time I saw it I freaked out.

If I did my math correct HW Error is .02 right now.

It's one day right now because I swapped the PSU out the yesterdayish.  Before same setup ran 5 days straight before i moved locations of the miners.  Moved them into the shop area from our hang out area.

I'm use to the x issue

HWI% =  (HW)/(HW + Diffa +Diffr + Diffs).  If my numbers are correct = (103,560)/(103,560 + 4,279,472 + 5632+0) = i get 2.37.  Am I wrong in my way of calculating hwi%?

Please tell me I am so I can clock my miner at 200
sr. member
Activity: 486
Merit: 262
rm -rf stupidity
All X's is firmware thing first time I saw it I freaked out.

If I did my math correct HW Error is .02 right now.

It's one day right now because I swapped the PSU out the yesterdayish.  Before same setup ran 5 days straight before i moved locations of the miners.  Moved them into the shop area from our hang out area.
hero member
Activity: 774
Merit: 500
Lazy Lurker Reads Alot
How come i see so high temps with so many fans cooling them
And all the X's lol
 
hero member
Activity: 818
Merit: 508
Has anyone with the flipped heatsinks with fans gone above 400?  I thought about trying 425 or 450.

I also do have my watercooled heat sinks from my Avalon2 setup that I just need to drill and tap some (checked where water jackets were) so if temps became a problem not to worried about that part.

Here is mine currently at 400.  Screenshot sucks even more because its a screenshot while logged in teamviewer LOL



They are both on 750W gold supplies right now due to some changes around with my rigs, but that one is an Enermax 1000W.  The screen shot is the right side one that has the bigger fans (95cfm)



How much damage are you doing, if any, with the current HWI%?  How long have you been running them?
sr. member
Activity: 486
Merit: 262
rm -rf stupidity
Has anyone with the flipped heatsinks with fans gone above 400?  I thought about trying 425 or 450.

I also do have my watercooled heat sinks from my Avalon2 setup that I just need to drill and tap some (checked where water jackets were) so if temps became a problem not to worried about that part.

Here is mine currently at 400.  Screenshot sucks even more because its a screenshot while logged in teamviewer LOL



They are both on 750W gold supplies right now due to some changes around with my rigs, but that one is an Enermax 1000W.  The screen shot is the right side one that has the bigger fans (95cfm)

legendary
Activity: 2128
Merit: 1005
ASIC Wannabe

I was trying to use the 'Restore to default' setting in my ANTminer today and it restarted automatically like it was supposed to but it doesn't let me log in. I shows the black LuCi screen and then moves to a page cannot be loaded screen.


I am tried used the hard reset by jumping the wires but it does not work.

Anyone else have this same problem?

the luci screen will load due to your browser cache - the actual antminer IP likely changed when you reset. try 192.168.1.99 or 192.168.2.99 if that does not work
legendary
Activity: 2128
Merit: 1005
ASIC Wannabe
Hi
 do you have any advice how to split AntminerS1 hash power?
 For example 4*50 GHs?
 Is it possible?
thanks

not possible.