It's rather amazing how poor quality those pumps are, I've been keeping my C1 cool with one of these little guys http://www.ebay.com/itm/12V-DC-CPU-Cooling-CAR-Brushless-Water-Oil-Pump-Waterproof-Submersible-AP-/121458053302?pt=LH_DefaultDomain_0&hash=item1c4776d0b6

$6, no problems at all.



Those are water fountain / fish tank pumps which do work, but have half the pushing power and height as the C1 rated pump. They also have no reservoir, unless you have that pump sitting inside a small bucket of coolant or something?

It's rather amazing how poor quality those pumps are, I've been keeping my C1 cool with one of these little guys http://www.ebay.com/itm/12V-DC-CPU-Cooling-CAR-Brushless-Water-Oil-Pump-Waterproof-Submersible-AP-/121458053302?pt=LH_DefaultDomain_0&hash=item1c4776d0b6

$6, no problems at all.



Those are water fountain / fish tank pumps which do work, but have half the pushing power and height as the C1 rated pump. They also have no reservoir, unless you have that pump sitting inside a small bucket of coolant or something?

From the specs that one is rated around 1/2 of volume pushed.   I would guess it's partially based on ambient temperature.  If OP has very cold ambient it will cool the coolant when in the tube, not just in the radiator.

Personally I would not go this route but I know a few through this thread have.  You would use anything that holds water and is big enough to put it in as a reservoir.  Reservoir's are not really anything special.


You'd be amazed at how little flow you really need for most water cooling systems. Although Bitmain chose fairly small hose ports, the blocks are not crazy restrictive (and if they were, it would be a bad design) plus 2 meters of head is pretty good for a small pump. It takes a lot of energy to heat water significantly during the 3-4 seconds it spends in the C1 water blocks before it heads back to the radiator.

Here's a screenshot of the current temps of my C1 and it's not that cold in my basement, approximately 60F (15.5C)



Picture of flow obtained with the little pump



Got a Jalapeno still hashing away there?  It looks stock, is it modded at all? 

Got a
legendary
Activity: 1456
Merit: 1000
I seen that 6 fan mod as well, digging through my scrap parts now for more fans Smiley and my wife criticizes me for my piles of old computers hahaha

I have a odd number with only adding two.  I thought about adding a third on backside but with winter air it really does not make a lot of difference Smiley. Maybe during summer I will add the last one.

Ended up adding another fan.  Now have 6 fans on each radiator.  They were cheap fans I had laying in my parts pile.   If you have a high RPM fan to add it really could make a difference on amount of air though.
legendary
Activity: 1246
Merit: 1024
Anyone, preferably in Asia region, have a C1 (batch 2 preferred) that they want to sell for a reasonable price? If you have something to offer please PM me. Thanks.
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
If those X's do come back what would be my next step short of a RMA? Thermal paste issue? I check underneath the miner and there is no puddles . Not a fan of opening the case up, yes I am that lazy haha. What do you think thermal paste issue or potential leak?

Neither of those would cause what you have, its just something that occurs.

At any rate since I got your attention what is the best fluid for the miner, I got primochill in it now as thats what amazon had for a good price.

Primochill is fine, everything will be similar.

Also if i do need to open it up which board is board #2 if viewing from the front? second from left or second from right?

For me when looking at the fan, its second from the right but it might be different for you.

and any diagrams of the asic chips which ones are represented by those with the x's? ooooooox xooooooo

Not sure as the board labels don't seem to be in a sensible order.

And what would be the science behind why a psu power down reset would make them disappear versus a reboot form the software panel? I tried that 3 times before doing the PSU reset and when i rebooted from the panel after 235-30 mins the X's kept coming back.

Chips need the voltage change to start back up, which the software reset doesn't do.
legendary
Activity: 1456
Merit: 1000
I seen that 6 fan mod as well, digging through my scrap parts now for more fans Smiley and my wife criticizes me for my piles of old computers hahaha

I have a odd number with only adding two.  I thought about adding a third on backside but with winter air it really does not make a lot of difference Smiley. Maybe during summer I will add the last one.
full member
Activity: 174
Merit: 100
I seen that 6 fan mod as well, digging through my scrap parts now for more fans Smiley and my wife criticizes me for my piles of old computers hahaha

Wow just seen that link above that user "bitmain warranty" sent hehe I am so ordering one of those Smiley

Is that DHgate actually bitmain?

I Know thisis a bit off topic but since were discussing cooling mods anyone ever oil cool a antminer?
Can you oil cool a PSU?

I know the have been successfully oil cooling motherboards for years now. Just a curiosity

Still digging this cooling system haha http://youtu.be/K_gCnvsM-QY

full member
Activity: 174
Merit: 100
I did the hard reset thing, and no X's today yet I will be checking frequently. I have not modified any settings as far as clock or voltage goes. Its @ 250mhz voltage 0760  I dont overclock until the warranty expires Smiley bitmain warranty emailed me this morning guess they found that post. They said unless I got it from bitmaintech or bitmain store on ebay the warranty would have to be handled by the amazon seller I got it from ths guy www.amazon.com/shops/cryptocrane so i messaged him last night requesting a RMA have not heard back from him yet. Its the weekend. Hopefully will not see any more x's

One thing i did before hard reboot was fill in the top pool I had emptied the top 2 pools addresses and jumped to my third pool. When i switch pools i just remove the pool address and leave the username and pass for convienance. Not sure if that would cause a issue, i wouldnt think so but just in case, I filled in the top pool info.

So far so good like i said i will be keeping a very critical eye on it. But if I find any more X's And if the guy lets me return it I will be buying a S5 instead. He sells them for the same price Smiley

If those X's do come back what would be my next step short of a RMA? Thermal paste issue? I check underneath the miner and there is no puddles . Not a fan of opening the case up, yes I am that lazy haha.

What do you think thermal paste issue or potential leak?

Like i said so far 15hrs and no X's so hope it stays that way, hash rate has stabalized as well still wanders awider range than my S3+'s though. But it is averaging out correctly @ 1006.5 GHs avg. still technically not the 1008 Bitmain states is guranteed Smiley not sure what they mean by that? if its not 1008 they what take it back? Pretty sure guranteed probably means something different in china than it does here in the US.

At any rate since I got your attention what is the best fluid for the miner, I got primochill in it now as thats what amazon had for a good price. But is there any specific fluid better than the others for some special cooling property? Or are they all pretty much the same deionized low conductive fluid with anti-microbial and corrosion resistance? Care less about Dyes i dont have any black lights and not going to buy one just to light up some tubing Smiley I do got a flow meter coming with built in temp sensor and LED light, just so i can visuallly check things are pumping without having to focus in on the pump looking for movement.

Also if i do need to open it up
which board is board #2 if viewing from the front? second from left or second from right?
and any diagrams of the asic chips which ones are represented by those with the x's? ooooooox xooooooo

Like i said so far so good no x's yet just checked again
And what would be the science behind why a psu power down reset would make them disappear versus a reboot form the software panel? I tried that 3 times before doing the PSU reset and when i rebooted from the panel after 235-30 mins the X's kept coming back.

Does that indicate it was a software bug or something versus a hardware failure?
legendary
Activity: 1456
Merit: 1000
I added 2 fans for the fun of it on opposite side of radiator.  It seems to make it a little cooler.   The fan's i used are cheap (free after rebate) i had laying around.   I'm sure you could do a lot better on fan quality and see even cooler results.
legendary
Activity: 1246
Merit: 1024
Been wanting to order another C1 for over a week but with the drop in BitCoin value, all the deposits from the pool seem to not help with getting enough for one.  Wondering if there are still any coupons for C1's out or are they all expired?


Mine have expired. I have been looking for a few coupons also. Would not mind getting a C1 if I could get the price down more to compensate for the low btc value.
sr. member
Activity: 338
Merit: 250
Been wanting to order another C1 for over a week but with the drop in BitCoin value, all the deposits from the pool seem to not help with getting enough for one.  Wondering if there are still any coupons for C1's out or are they all expired?
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
Okay had my antminer c1 7 days and have not overclocked or anything and today I am gettings x's
Chain   ASICS   Frequency    Temp               X.s errr!!!!!!
2         16           250           44            ooooooox xooooooo

Man I am glad I did not over clock

So what should i do?

I am running on a brand new evga 1300w G2 all 8 pcie hooked up
Only miner on that 20amp circuit so shouldnt be a power issue

Got a link for the RMA or should i send it back through amazon (cryptocrane)
This Sucks !!!!!

I have 9 s3+'s all overclocked and have never had a x they have been hashing at 505GHS steady for 4 mos. and have never seen a x.

Give it a hard reset (via PSU) before you send it back, and then let us know what voltage setting your on currently.
donator
Activity: 792
Merit: 510
@rpandassociates,

PM sent!

Warranty Needs, you can always send the products to the following address.

Bitmain Warranty
3700 Quebec Street
Unit 100-239
Denver, Colorado 80207

Tel: +1-844-248-6246 Option 2


*2-way shipping fee or replacement cost may apply to the unit purchased from other than Bitmaintech.com or Amazon Seller "Bitmain" or Credit Card Purcahse via

http://www.dhgate.com/wholesale/products/ff8080814999aafa0149c0d2594761cf.html
hero member
Activity: 924
Merit: 500
Who run the C1 with hot ambient temperatur. If the temperature is hotter than 30C in the room. I want to know if the miner is still stable?

Due to pump failure I have 2x C1 with one radiator and room temp is 40-45C, C1 temps are 58-63C. Working well.
full member
Activity: 174
Merit: 100
Okay had my antminer c1 7 days and have not overclocked or anything and today I am gettings x's
Chain   ASICS   Frequency    Temp               X.s errr!!!!!!
2         16           250           44            ooooooox xooooooo

Man I am glad I did not over clock

So what should i do?

I am running on a brand new evga 1300w G2 all 8 pcie hooked up
Only miner on that 20amp circuit so shouldnt be a power issue

Got a link for the RMA or should i send it back through amazon (cryptocrane)
This Sucks !!!!!


I have 9 s3+'s all overclocked and have never had a x they have been hashing at 505GHS steady for 4 mos. and have never seen a x.
legendary
Activity: 1274
Merit: 1000
Personal text my ass....
It's rather amazing how poor quality those pumps are, I've been keeping my C1 cool with one of these little guys http://www.ebay.com/itm/12V-DC-CPU-Cooling-CAR-Brushless-Water-Oil-Pump-Waterproof-Submersible-AP-/121458053302?pt=LH_DefaultDomain_0&hash=item1c4776d0b6

$6, no problems at all.



Those are water fountain / fish tank pumps which do work, but have half the pushing power and height as the C1 rated pump. They also have no reservoir, unless you have that pump sitting inside a small bucket of coolant or something?

It's rather amazing how poor quality those pumps are, I've been keeping my C1 cool with one of these little guys http://www.ebay.com/itm/12V-DC-CPU-Cooling-CAR-Brushless-Water-Oil-Pump-Waterproof-Submersible-AP-/121458053302?pt=LH_DefaultDomain_0&hash=item1c4776d0b6

$6, no problems at all.



Those are water fountain / fish tank pumps which do work, but have half the pushing power and height as the C1 rated pump. They also have no reservoir, unless you have that pump sitting inside a small bucket of coolant or something?

From the specs that one is rated around 1/2 of volume pushed.   I would guess it's partially based on ambient temperature.  If OP has very cold ambient it will cool the coolant when in the tube, not just in the radiator.

Personally I would not go this route but I know a few through this thread have.  You would use anything that holds water and is big enough to put it in as a reservoir.  Reservoir's are not really anything special.


You'd be amazed at how little flow you really need for most water cooling systems. Although Bitmain chose fairly small hose ports, the blocks are not crazy restrictive (and if they were, it would be a bad design) plus 2 meters of head is pretty good for a small pump. It takes a lot of energy to heat water significantly during the 3-4 seconds it spends in the C1 water blocks before it heads back to the radiator.

Here's a screenshot of the current temps of my C1 and it's not that cold in my basement, approximately 60F (15.5C)



Picture of flow obtained with the little pump




I have 3 C1's sitting right next to one another, in the same room and all three have different temps. Ranging from 29-43. It all depends on the miner rig. I have 6 of them and I'm aware of which 2 run hotter than the others. Why they run hotter? Most likely a quality control issue with the thermal or some other thing. None are exactly the same.
hero member
Activity: 637
Merit: 502
Thanks for your response DolphinHeart.

When I look at the web console we see Chain 1 to 4. If I look at a miner with the fan facing me where are chain 1 to 4?

On my unit it would be the right most unit, but there may not be any pattern to it.

I will open the hood.
legendary
Activity: 1666
Merit: 1185
dogiecoin.com
Thanks for your response DolphinHeart.

When I look at the web console we see Chain 1 to 4. If I look at a miner with the fan facing me where are chain 1 to 4?

On my unit it would be the right most unit, but there may not be any pattern to it.
hero member
Activity: 637
Merit: 502
Thanks for your response DolphinHeart.

When I look at the web console we see Chain 1 to 4. If I look at a miner with the fan facing me where are chain 1 to 4?
newbie
Activity: 2
Merit: 0
Who run the C1 with hot ambient temperatur. If the temperature is hotter than 30C in the room. I want to know if the miner is still stable?

I was running 7 C1s in South Florida, had an A/C running but in a large room so didn't do much. The room was definitely getting up to almost 30C in the room with all miners running overclocked.

Miner temperature was over 40C... close to 47C sometimes and were all running great!

I had two of them in a room with no A/C, stock clock.. they were running around 42C and also running stable.
full member
Activity: 154
Merit: 100
Hi all,
My C1's pump broke, no worky...
is there any place in the US where to buy a replacement? i know syscooling carries it, but it seems to be sent from China...
anyone found a replacement that can be used? thanks
While you searching for replacements in USA,you could contact us to ask for RMA,please send emails to [email protected] with pictures or short video.
My friend that ordered for both of us sent emails to you guys, but said he got no response when sending the email for the RMA. What can we do?
TO [email protected]?She received nothing.I will send you personal messages,please check pm box.
Pages: